Difference between revisions of "Laser Control"
From Hall A Wiki
(→Diode Driver) |
(→Condition) |
||
Line 37: | Line 37: | ||
The section shows all the status bit, only three of them need to be paid attention | The section shows all the status bit, only three of them need to be paid attention | ||
− | Only '''Output ON/OFF | + | Only '''Output ON/OFF State''' is expected to be ON during normal condition. |
− | # | + | |
+ | Any other status bit should be off during production. Here I list some common problems | ||
+ | |||
+ | # Output Outside Tolerance: This is on when the laser current is ramping up or far away from the setpoint. | ||
+ | # Interlock Disabled: When the interlock is broken for some reason. | ||
=== Temperature Controller === | === Temperature Controller === |
Revision as of 18:04, 11 March 2009
Contents
Laser Control Menu
- Log onto hacsbs2 using account hacuser, password is on the wall.
- enter the directory Hall_A_Tools and execute NewTools
- EOS menu -> EDM(HLA Main) ->Polarized He3 -> Main Laser Control
COMET Laser Control
Each of the COMET Laser Control is divided into to parts representing two controllers we're using at the same time as you see in the snapshot.
- The top one is for the Diode Driver, which is the power supply of the laser diode and controls the current.
- The buttom one is for the Temperature Controller, which is controlling the diode temperature so that the wavelength of the output laser is stablized.
Diode Driver
The control of the diode driver has three sections:
Status
There are four clickable options and three indicators
- Indicator Comm: Shows the communication status, it should stay green when the communication to the device is good
- Options Disable and Enable: Used to enable or disable the laser. The check marks will not be updated automatically, so some time it's may not be in the right place.
- Second Indicator: Broken... and always in red....
- Options Remote and Local: Used to switch between remote and local mode. The GUI can only read back status and send commends in Remote mode.
- Third Indicator: Green means Remote mode and Yellow means Local mode.
Current
The unit in this section is wrong, and should be A instead of mW
- Photo Diode Current: Current read back of the laser diode.
- Set Current: Only editable place in this section. One can change the laser current by putting new values into the window then hitting enter key.
- Current SetPoint: Read back the current setpoint. If one changed the current, this read back value is expected to be changed if the change is succeeded.
Condition
The section shows all the status bit, only three of them need to be paid attention
Only Output ON/OFF State is expected to be ON during normal condition.
Any other status bit should be off during production. Here I list some common problems
- Output Outside Tolerance: This is on when the laser current is ramping up or far away from the setpoint.
- Interlock Disabled: When the interlock is broken for some reason.
Temperature Controller
FAP Laser Control
Discontinued...
Currently Used Lasers
- COMET 1 (W&M): 35A, 26C
- COMET 2 (Rutgers): 34A, 20C
- COMET 3 (JLab): 36A, 25C