Difference between revisions of "Run Plan"
From Hall A Wiki
Line 5: | Line 5: | ||
− | 1. | + | 1. <span style="color:#ff0000"> HRSs calibration with C(e,e') (elastic) with/ without sleeves. </span> |
Line 11: | Line 11: | ||
− | 2. Momentum scane for BigBite calibration, H(e,e'p) Kin [https://hallaweb.jlab.org/wiki/index.php/Kinematics#H.28e.2Ce.27p.29_HRS.28L.29_and_BigBite A 1,2,3]. | + | 2. <span style="color:#ff0000">Momentum scane for BigBite calibration, H(e,e'p) Kin [https://hallaweb.jlab.org/wiki/index.php/Kinematics#H.28e.2Ce.27p.29_HRS.28L.29_and_BigBite A 1,2,3].</span> |
Line 17: | Line 17: | ||
− | 3. | + | 3. <span style="color:#ff0000"> Continue calibration of BigBite H(e,e'p), D(e,e'p) and C(e,e'p) Kin [https://hallaweb.jlab.org/wiki/index.php/Kinematics#H.28e.2Ce.27p.29_HRS.28L.29_and_BigBite A 4,5], [https://hallaweb.jlab.org/wiki/index.php/Kinematics#Full_acceptance_calibration_of_BigBite_C.28e.2Ce.27p.29 B 1,2] and [https://hallaweb.jlab.org/wiki/index.php/Kinematics#Full_acceptance_calibration_of_BigBite_d.28e.2Ce.27p.29 C1] </span> |
* Move BigBite to backward angle (should allow HRSR at ~70 deg) | * Move BigBite to backward angle (should allow HRSR at ~70 deg) | ||
Line 25: | Line 25: | ||
− | 4. | + | 4. <span style="color:#ff0000"> Calibration of the HAND with H(e,e'p) Kin [https://hallaweb.jlab.org/wiki/index.php/Kinematics#H.28e.2Ce.27p.29_HRS.28L.29_and_Neutron_Array_for_protons D1].</span> |
− | 5. | + | 5. <span style="color:#ff0000"> Continue calibration of HRSs with quasi elastic scattering C(e,e'p) Kin [https://hallaweb.jlab.org/wiki/index.php/Kinematics#Quasi_Elastic_C.28e.2Ce.27p.29 G 1,2].</span> |
Line 35: | Line 35: | ||
− | 6. | + | 6. <span style="color:#ff0000"> Continue calibration of HRSs with quasi elastic scattering C(e,e'p) Kin [https://hallaweb.jlab.org/wiki/index.php/Kinematics#Quasi_Elastic_C.28e.2Ce.27p.29_2 G 3,4]</span> |
− | 7. | + | 7. <span style="color:#ff0000"> HAND neutron efficiency calibration.Kin [https://hallaweb.jlab.org/wiki/index.php/Kinematics#d.28e.2Ce.27pn.29_x.3C1_HRS.28L.29.2C_HRS.28R.29_and_Neutron_Array E 1,2].</span> |
Line 45: | Line 45: | ||
− | 8. D(e,e'pn), Establish triple coincidence at x>1 (Kin Pmiss = 250 MeV/c) | + | 8. <span style="color:#ff0000">D(e,e'pn), Establish triple coincidence at x>1 (Kin Pmiss = 250 MeV/c) </span> |
Revision as of 06:48, 13 April 2010
Calibration
- Tune beam to 1 pass, Set HRSL(-) and HRSR(-) at 15 (-15) deg.
1. HRSs calibration with C(e,e') (elastic) with/ without sleeves.
- Move HRS(R) to 12.5 deg change polarity to HRSR(+), Set BigBite at 68 Deg.
2. Momentum scane for BigBite calibration, H(e,e'p) Kin A 1,2,3.
- Energy change 1 pass to 2 pass.
3. Continue calibration of BigBite H(e,e'p), D(e,e'p) and C(e,e'p) Kin A 4,5, B 1,2 and C1
- Move BigBite to backward angle (should allow HRSR at ~70 deg)
- Put the Neutron array (without the lead wall) at 50 Deg and 15 meters from target.
4. Calibration of the HAND with H(e,e'p) Kin D1.
5. Continue calibration of HRSs with quasi elastic scattering C(e,e'p) Kin G 1,2.
- Put the BigBite at 99 Deg (magnet on detector off) and HAND behind and install lead wall. Switch the polarity of HRSs to HRSL(+) and HRSR(-).
6. Continue calibration of HRSs with quasi elastic scattering C(e,e'p) Kin G 3,4
7. HAND neutron efficiency calibration.Kin E 1,2.
- Tune beam to 4 pass, switch HRSs polarity to HRSL(-) and HRSR(+).
8. D(e,e'pn), Establish triple coincidence at x>1 (Kin Pmiss = 250 MeV/c)
- Singles rates study