Difference between revisions of "Laser"
From Hall A Wiki
(→Current Adjustment) |
(→Current Adjustment) |
||
Line 95: | Line 95: | ||
|1.96 | |1.96 | ||
|} | |} | ||
− | [[Image: | + | [[Image:coherent5power.JPG]] |
====Temperature Adjustment==== | ====Temperature Adjustment==== |
Revision as of 13:30, 14 June 2010
Single FAP Lasers
Power Test Result of Single FAP Lasers
Coherent #4
Current Adjustment
Temperature: 17.2 C
Current (A) | Laser Power (W) | Central Wavelength (nm) | FWHM (nm) |
---|---|---|---|
10 | 3.72 | 792.50 | 1.98 |
15 | 8.85 | 793.60 | 1.54 |
20 | 13.9 | 794.17 | 2.35 |
25 | 18.7 | 794.86 | 1.62 |
30 | 23.3 | 795.84 | 2.08 |
35 | 27.9 | 796.67 | 2.07 |
Temperature Adjustment
Temperature: 17.1 C
Centroid: 795.71 nm
Temperature: 17.2 C
Centroid: 795.77 nm
Temperature: 17.3 C
Centroid: 795.83 nm
Coherent #5
Current Adjustment
Temperature: 19.4 C
Current (A) | Laser Power (W) | Central Wavelength (nm) | FWHM (nm) |
---|---|---|---|
10 | 3.73 | 793.15 | 1.83 |
15 | 8.86 | 793.67 | 1.61 |
20 | 13.9 | 794.42 | 2.12 |
25 | 18.9 | 795.12 | 1.95 |
30 | 23.7 | 795.93 | 1.85 |
35 | 28.4 | 796.67 | 1.96 |
Temperature Adjustment
Temperature: 19.9 C
Centroid: 795.68 nm
Temperature: 20.0 C
Centroid: 795.71 nm
Temperature: 20.1 C
Centroid: 795.79 nm
DUO FAP Lasers
COMET Lasers
Power Test Result of COMET Lasers
Test Condition
- Diode Temperature: 25.0 C
Jlab COMET Laser I
Diode Current (A) | Laser Power (W) | Central Wavelength (nm) | Wavelength FWHM (nm) |
---|---|---|---|
10 | 1.21 | 794.86 | 0.63 |
15 | 5.1 | 794.91 | 0.63 |
20 | 9.2 | 794.95 | 0.65 |
25 | 13.3 | 795.01 | 0.66 |
30 | 17.6 | 795.06 | 0.66 |
35 | 22.0 | 795.14 | 0.68 |
Test Condition
- Diode Temperature: 30.0 C
Jlab COMET Laser II
Diode Current (A) | Laser Power (W) | Central Wavelength (nm) | Wavelength FWHM (nm) |
---|---|---|---|
10 | 0.93 | 794.84 | 0.51 |
15 | 4.97 | 794.89 | 0.56 |
20 | 9.2 | 794.95 | 0.57 |
25 | 13.7 | 795.02 | 0.60 |
30 | 18.2 | 795.08 | 0.61 |
35 | 22.7 | 795.10 | 0.61 |
36 | 23.5 | 795.12 | 0.59 |
40 | 26.9 | 795.16 | 0.60 |
Test Condition
- Room Temperature: 22.9 C
- Diode Temperature: 20.0 C
W&M COMET Laser
Diode Current (I) | Driving Voltage (V) | Cooling Current (I) | Laser Power (W) | Central Wavelength (nm) | Wavelength FWHM (nm) |
---|---|---|---|---|---|
10 | 1.66 | 1.71 | 1.34 | 794.79 | 0.58 |
15 | 1.72 | 2.18 | 5.82 | 794.83 | 0.50 |
20 | 1.78 | 2.57 | 10.5 | 794.88 | 0.51 |
25 | 1.84 | 2.77 | 15.1 | 794.91 | 0.53 |
30 | 1.90 | 3.31 | 19.7 | 794.94 | 0.57 |
35 | 1.95 | 4.18 | 24.3 | 795.01 | 0.57 |
40 | 2.01 | 4.95 | 28.6 | 795.06 | 0.62 |
44 | 2.05 | 5.53 | 32.1 | 795.11 | 0.64 |
Rutgers COMET Laser
Diode Current (I) | Driving Voltage (V) | Cooling Current (I) | Laser Power (W) | Central Wavelength (nm) | Wavelength FWHM (nm) |
---|---|---|---|---|---|
10 | 1.67 | 1.56 | 2.67 | 794.84 | 0.55 |
15 | 1.74 | 1.99 | 7.18 | 794.90 | 0.53 |
20 | 1.80 | 2.45 | 11.9 | 794.98 | 0.52 |
25 | 1.87 | 2.96 | 16.5 | 795.03 | 0.50 |
30 | 1.93 | 3.56 | 21.1 | 795.09 | 0.52 |
35 | 1.99 | 4.29 | 25.6 | 795.15 | 0.56 |
40 | 2.05 | 5.18 | 30.3 | 795.22 | 0.60 |
Grading for The Fiber Tips
Vertical
75m# | 75mLR | 75mH | 5to1# | 5to1 |
---|---|---|---|---|
N6 | 3 | 5- | 3 | 4 |
N7 | 5 | 4+ | 4 | 4+ |
N8 | 4 | 5- | 5 | 5- |
N9 | 5 | 5 | 1 | 5 |
N10 | 2 | 5 | 2 | 4- |
Transverse
75m# | 75mLR | 75mH | 5to1# | 5to1 |
---|---|---|---|---|
N1 | 3 | 4- | 5 | 3+ |
N2 | 3+ | 4- | 1 | 4+ |
N3 | 4 | 2 | 3 | 2 |
N4 | 5 | 4+ | 4 | 4+ |
N5 | 4 | 5 | 2 | 5 |
Long.
75m# | 75mLR | 75mH | 5to1# | 5to1 |
---|---|---|---|---|
01 | 3 | 1 | 3+ | |
02 | 1 | 2 | 3+ | |
03 | 0 | 3 | 0 | |
04 | 2 | 5 | 3+ | |
05 | 3 | 4 | 4 |