[http://hallaweb.jlab.org/experiment/E07-006/wire_chambers/db_algoritm.pdf Mapping Procedure] | [http://hallaweb.jlab.org/experiment/E07-006/wire_chambers/db_algoritm.pdf Mapping Procedure] | ||
+ | |||
+ | ==BigBite Wire Chamber HV Trip Recovery Procedure== | ||
+ | 1. Chamber 1 HV channel: 14.0 14.1 14.2 14.3 <br> | ||
+ | 2. Chamber 2 HV channel: 15.0 15.1 15.2 15.3 <br> | ||
+ | |||
+ | When the chamber trips, please turn off all the HV channels corresponding to that chamber. Wait till all the HV are lower than 500V. <br> | ||
+ | Then bring up all HV channels for that chamber to the original value. This can be done by turn on and off the channel in the HV gui!!<br> | ||
==Links== | ==Links== |
Revision as of 10:11, 2 February 2011
BigBite Wire Chamber HV Trip Recovery Procedure
1. Chamber 1 HV channel: 14.0 14.1 14.2 14.3
2. Chamber 2 HV channel: 15.0 15.1 15.2 15.3
When the chamber trips, please turn off all the HV channels corresponding to that chamber. Wait till all the HV are lower than 500V.
Then bring up all HV channels for that chamber to the original value. This can be done by turn on and off the channel in the HV gui!!