Difference between revisions of "Gemeel122 log 375"
From Hall A Wiki
Line 18: | Line 18: | ||
|- | |- | ||
| 379 || || Mar 9 2011 || || || 3.8V || || junk | | 379 || || Mar 9 2011 || || || 3.8V || || junk | ||
+ | |- | ||
+ | | 380 || || Mar 10 2011 || || || 3.8V || || junk while fixing problem. Not clear what the fix was. Maybe the connecting cable between gassiplex boards was not connected securely | ||
+ | |- | ||
+ | | 381 || || Mar 10 2011 || || || 3.8V || || junk, low voltage off! | ||
+ | |- | ||
+ | | 382 || || Mar 10 2011 || || || 3.8V || || junk, low voltage off! | ||
+ | |- | ||
+ | | 383 || Ped || Mar 10 2011 || || || 3.8V || || Good pedestal Chamber 1 | ||
+ | |- | ||
+ | | 384 || Cosmic || Mar 10 2011 || || || 3.8V || || Tried 55Fe source. Not good | ||
+ | |- | ||
+ | | 385 || Cosmic || Mar 10 2011 || || || 3.8V || || 90Sr source, center of chamber 1 | ||
+ | |- | ||
+ | | 386 || Cosmic || Mar 10 2011 || || || 3.8V || || 90Sr source, move around chamber 1 | ||
+ | |- | ||
+ | | 387 || Cosmic || Mar 10 2011 || 15:03 || || 3.86V || || 90Sr source, move around chamber 1 | ||
+ | |- | ||
+ | | 388 || Ped || Mar 10 2011 || || || 3.86V || || adjusted Ch 3 amplifier DC offset | ||
+ | |- | ||
+ | | 389 || Ped || Mar 10 2011 || || || 3.86V || || Noticed ch 3 Y threshold had a gap | ||
+ | |- | ||
+ | | 390 || Ped || Mar 10 2011 || || || 0V || || Connect up Chamber 2, play with DC offset for Ch 2 | ||
+ | |- | ||
+ | | 391 || Ped || Mar 10 2011 || || || 0V || || Pedestal for Ch 1,2 and 3. Need to study | ||
+ | |- | ||
+ | | || || || || || || || | ||
+ | |- | ||
|- | |- | ||
|} | |} |
Revision as of 19:01, 10 March 2011
RUN # | Source/Cosmic/Pedestal | Date | Start Time | End Time | HV | # of events | notes |
---|---|---|---|---|---|---|---|
376 | Pedestal | Mar 9 2011 | 11:19:40 | 11:20:30 | 3.8V | 1593 | Chamber 1, problem with Y pedestals |
377 | Pedestal | Mar 9 2011 | 3.8V | junk, Do not see Y signals on the scope | |||
378 | Pedestal | Mar 9 2011 | 3.8V | junk, try changing board for Y readout. | |||
379 | Mar 9 2011 | 3.8V | junk | ||||
380 | Mar 10 2011 | 3.8V | junk while fixing problem. Not clear what the fix was. Maybe the connecting cable between gassiplex boards was not connected securely | ||||
381 | Mar 10 2011 | 3.8V | junk, low voltage off! | ||||
382 | Mar 10 2011 | 3.8V | junk, low voltage off! | ||||
383 | Ped | Mar 10 2011 | 3.8V | Good pedestal Chamber 1 | |||
384 | Cosmic | Mar 10 2011 | 3.8V | Tried 55Fe source. Not good | |||
385 | Cosmic | Mar 10 2011 | 3.8V | 90Sr source, center of chamber 1 | |||
386 | Cosmic | Mar 10 2011 | 3.8V | 90Sr source, move around chamber 1 | |||
387 | Cosmic | Mar 10 2011 | 15:03 | 3.86V | 90Sr source, move around chamber 1 | ||
388 | Ped | Mar 10 2011 | 3.86V | adjusted Ch 3 amplifier DC offset | |||
389 | Ped | Mar 10 2011 | 3.86V | Noticed ch 3 Y threshold had a gap | |||
390 | Ped | Mar 10 2011 | 0V | Connect up Chamber 2, play with DC offset for Ch 2 | |||
391 | Ped | Mar 10 2011 | 0V | Pedestal for Ch 1,2 and 3. Need to study | |||