LHRS ADC and TDC numbering
For g2p the we replaced the following PMT's on S1: 2R,5R,6R,5L and 6L
Trigger Efficiency: For Run 1795 efficiency was 99.33%
S1 Cable ADC TDC ROC/Slot/Channel ROC/Slot/Channel ------------------------------------------ L1 5/20/32 5/23/0 L2 5/20/33 5/23/1 L3 5/20/34 5/23/2 L4 5/20/35 5/23/3 L5 5/20/36 5/23/4 L6 5/20/37 5/23/5 ----------------------------------------- R1 5/20/38 5/23/8 R2 5/20/39 5/23/9 R3 5/20/40 5/23/10 R4 5/20/41 5/23/11 R5 5/20/42 5/23/12 R6 5/20/46 5/23/13
RHRS ADC and TDC numbering
Trigger Efficiency: For Run 20926 efficiency was 99.22%
S2m Cable ADC TDC ROC/Slot/Channel ROC/Slot/Channel ------------------------------------------ L1 1/23/16 2/12/32 L2 1/23/17 2/12/33 L3 1/23/18 2/12/34 L4 1/23/19 2/12/35 L5 1/23/20 2/12/36 L6 1/23/21 2/12/37 ----------------------------------------- R1 1/23/22 2/12/40 R2 1/23/23 2/12/41 R3 1/23/24 2/12/42 R4 1/23/25 2/12/43 R5 1/23/26 2/12/44 R6 1/23/27 2/12/45