DAQ September 25th 2020
What detectors will be used for GMn and GEn?
BigBite (Shower, GRINCH, GEM, Hodoscope) and HCAL
Is the hardware fully specified? (Types and numbers crates and modules specified.) Are there any design choices not made?
Yes
Is there firmware that needs to be developed? When will it be ready? Can it be tested without beam?
GEM readout firmware
What DAQ modules are used?
FADC F1 V1190 V792 TI TS TD MPD
What is the trigger? NIM? Is it designed?
Bigbite Shower analog sum
Is hardware for trigger fully specified?
Yes
What version of CODA will be used?
CODA3
When will full DAQ system be assembled? (Will this be in hall or elsewhere?)
In Hall Spring 2021
What can not be tested without beam?
What detector test DAQs exist? Are they all used for the full DAQ?
GRINCH BB Shower INFN GEM UVA GEM HCAL
Yes
What is the status of GEM readout?
Optical readout being tested, new MPD firmware in development for zero supression, common noise supression and packing in 32 bit words
Is all the hardware in hand? Do all the cables exist?
Is any borrowed hardware used and if so has possession of that hardware been taken?
Need to get 10 FADCs from electronics group and 2 SD
Is any needed hardware currently loaned out for non SBS/Bigbite uses? When will it be returned?
What are the typical and maximum data rates?
Is networking and computing sufficient?
Yes
Will analysis software be ready enough for at least online data quality checks?
Yes
What work is needed from FEDAQ group? Does work have sufficient priority?
GEM firmware, highest priority