G2p s1

From Hall A Wiki
Revision as of 16:19, 5 January 2012 by Rbziel (Talk | contribs) (LHRS ADC and TDC numbering)

Jump to: navigation, search

LHRS ADC and TDC numbering

LHRS S1 ADC/TDC Plots

For g2p the we replaced the following PMT's on S1: 2R,5R,6R,5L and 6L

Trigger Efficiency: For Run 1795 efficiency was 99.33%

 S2m Cable         ADC                TDC
            ROC/Slot/Channel   ROC/Slot/Channel
------------------------------------------
L1            5/20/32            5/23/0
L2            5/20/33            5/23/1
L3            5/20/34            5/23/2
L4            5/20/35            5/23/3
L5            5/20/36            5/23/4
L6            5/20/37            5/23/5
-----------------------------------------
R1            5/20/38            5/23/8
R2            5/20/39            5/23/9
R3            5/20/40            5/23/10
R4            5/20/41            5/23/11
R5            5/20/42            5/23/12
R6            5/20/46            5/23/13

RHRS ADC and TDC numbering

RHRS S1 ADC/TDC Plots

Trigger Efficiency: For Run 20926 efficiency was 99.22%

 S2m Cable         ADC                TDC
            ROC/Slot/Channel   ROC/Slot/Channel
------------------------------------------
L1            1/23/32            2/23/0
L2            1/23/33            2/23/1
L3            1/23/34            2/23/2
L4            1/23/35            2/23/3
L5            1/23/36            2/23/4
L6            1/23/37            2/23/5
-----------------------------------------
R1            1/23/38            2/23/8
R2            1/23/39            2/23/9
R3            1/23/40            2/23/10
R4            1/23/41            2/23/11
R5            1/23/42            2/23/12
R6            1/23/46            2/23/13