Online scaler rates - xscaler

From Hall A Wiki
Revision as of 14:15, 21 March 2014 by Kalyan (Talk | contribs)

Jump to: navigation, search
  • Raw rates of trigger and detector channels can be accessed using a GUI. Below are the instructions for opening "xscaler" GUI
  • These screens are generally already open on the agen5 machine (above the DAQ machine)
  • If it is xscaler is not open then follow these instructions:
  • login as a-onl on adaql1 or adaql2 machines (eg: "ssh a-onl@adaql1" )
  • passwords are written on a note and available in the counting house
  • type "goxscaler" and follow the instructions printed on the screen
  • type "./xscaler Left" or "./xscaler Right" to access xscaler display
  • Select the "Trig-Cher-S0" tab on the top of the window


12_GeV_March_2014_running