Old MolPol DAQ Analysis

From Hall A Wiki
Revision as of 15:55, 13 August 2018 by Cameronc (Talk | contribs) (New page: ===Making Polarization measurements=== <ol> <li>Start '''dbedit''' on '''adaq1''', select "'''mollerpol_l'''" database and set in "'''beam_pol'''" configuration table in row "'''code'''" ...)

(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to: navigation, search

Making Polarization measurements

  1. Start dbedit on adaq1, select "mollerpol_l" database and set in "beam_pol" configuration table in row "code" parameter "adcevents" from 9 to 2: " ... adcevents=2"
  2. Make at least two CODA runs in order to use both coil polarities.
  3. Data analysis:
    • old DAQ: adaq1:~/paw/moller/
      > paw
      paw> exec run run=15625
      paw> exec lg_spectra run=15625
      paw> exec time run=15625
      paw> lcd mag_optim
      paw> exec anpow_set e0=7.37 (E0 - beam energy in GeV)
      paw> exec asym11 anpow=0.7735 gate=0.033 run=15625 (gate=0.033 for 30Hz helicity frequency and gate=0.0008 for 1kHz)