Polhe3 electronics list 2019
From Hall A Wiki
Revision as of 18:07, 29 March 2019 by Jhchen (Talk | contribs) (Created page with "== current list == holding field (3 set) 2 KEPCO powersupply (good for voltage mode). From Temple 1 HP 6675A powersupply (good for current mode). Tag: F24642? | do not se...")
current list
holding field (3 set)
2 KEPCO powersupply (good for voltage mode). From Temple 1 HP 6675A powersupply (good for current mode). Tag: F24642? | do not see the Ftag 2 DS345 function generator (control offset) . Tag: F220640, F220633 need 1 more DS345 to have three coil at same time, we have 1 spare | Can be F220931 spare 1 wavetek80 function generator (trigger). Tag: F218799 3 Fluke 45 multimeter | F220625 F218805 F220706 1 rotation box 1 DC power supply Agilent E3634A(correction coil. Tag: F223897
? 2 more CC power supply? ? 2 More current mode DC power?
RF (2 set RF)
1 HP 3324 function generator (RF signal) F221192 1 AG 1201 amplifier (RF amplifier) UVa 95302 1 capacitor box (match RF coil impedance) Temple
NMR (3 sets pickup)
3 SR560 preamplifier (pickup signal). (Changed: Tag: F218549, other has no tag) PC: F223618 TC_US: F223619 TC_DS: F218546 need 1 SR560 to have three sets, we have 3 spare | Yes we have now 3 SR844 lockin amplifier (collect signal). Changed:Tag: F221327, F222287 PC: F225392 TC_US: F224123 TC_DS: F222287 1 DC power source 2040A (for convection) F220973 ? 2040A Value indicator seems malfunctioning F
pNMR with Lockin (1 set)
1 pulse RF function generator, DS345 F220930 1 reference RF function generator, Keysight 3324A, F220637 1 Trigger, WaveTek F220705 2 Switch, ZYSWA-2-50DR 1 Switch Power Supply, P33-5 Daburn Electronics 1 pre-Amplifier F233620 1 DAQ NI USB-6251 1 Lockin SR844
pNMR(Changed) (1 set)
1HP 3324A function generator (RF). Tag: F220637 1 wavetek80 function generator(trigger). Tag: F220705 1 DS345 function generator(RF signal). Tag: F220930 1 DS345 function generator (reference signal). Tag: F223622 2 SR560 preamplifier (pickup signal). Tag: F222818, F222281 2 switch 1 DC power supply HY3005F-3 with two output (for switch) 1 mixer 1 Tektronik TDS 1002B oscilloscope. Tag: F223617 1 DAQ card 1 Lockin SR844. Tag: F224123
EPR (1 set)
1 DS345 function generator(generate signal) , from Temple 1 SR620 (counter), Tag:F221219 1 HP E4400B function generator (generate signal), Tag: F221717 1 PerkinElmer 7265 lockin amplifier (collect signal), (Changed: Tag: F220937) | F218655 1 2100-L RF power Amplifier, Tag: 221221 1 2100-L RF power Amplifier, from UVa(95302) | Why need two? now this one is using for AFP aplifier 1 PI box, ?now using this one 2 PI box made by JLab electronic group ? what's the difference? Good as spare
?Need checking SR620 accuracy?
Density
Gone 1 Wavemeter WM-1210 NewFocus, Tag:F225363 1 Wavemeter New Focus WM-1210 F225420 1 tunable-diode-laser velocity-6300, Tag: F215521 1 3501 optical chopper, NewFocus, (Did not see:Tag: Caltech 000046958) F224359 2 7265 DSP lock-in amplifier, no Tag | F220937 (Broken) F220674 1 Lindberg/Blue Oven, Tag: F218904 | Glass fragments in the air flow way, should be concerned
Spare/EEL Downstair
1 DS345 F223622 2 SR560 F222281 F224365 1 DC Power HY3005F-3 F224364 1 RF Amplifier ENI2100L, Temple
Spare/EEL Upstair
1 SR620 F220628 1 RF Amplifer AG1201 F221662 1 SR560 F222818 Battery Broken 1 DS345 F220931(repaired one) For Field sweep? 1 Old DC Power 6673A 35V-60A F220093 1 DC Power 6675A F223986 1 Function Generator 3324A F225400 1 DC Power Supply E3634A F223964 1 SR830 F219883 2 Multimeter 34401A F211609 F220626(Seems Brand New) 3 DC Power Supply BK precesion 1901B
spare (before)
1 AG amplifier 2 HP 34401A multimeter 2 KEPCO powersupply (good for voltage mode) (listed in Field?) 1 lock-in amplifier SR830 1 HP E4400B (at UNH) ?still we have one for epr rf 1 SR620 3 SR560 Preamplifier. Tag: F223619, F223620(did not see this one), and other has no tag (F218546? written on top) 1 DS345 (at Duke) | ?still 1 6675A power supply (bought in Aug 2015) 1 6673A (old) 1 DC power supply Agilent E3634A 2 PI box
broken
Gone 1 Wavemeter WA-1100 Burleigh(broken) 1 DS345 | Repaird? 1 EPR/density lockin? need check again maybe one of the 7265