How to solve 100% dead time problem

From Hall A Wiki
Revision as of 09:43, 15 December 2008 by Kalyan (Talk | contribs) (New page: If there is a 100% deadtime for more than a min, stop the run, kill coda (kcoda) and restart the coda by logging into a-onl account(even if you are in a-onl account). In most cases this wi...)

(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to: navigation, search

If there is a 100% deadtime for more than a min, stop the run, kill coda (kcoda) and restart the coda by logging into a-onl account(even if you are in a-onl account). In most cases this will solve the problem and if this doesn't help then reboot TS12 and start coda again. If this doesn't help then reboot all the crates except ROC14 and ROC15 and start coda again.