Cosmics in TEDf
From Hall A Wiki
Revision as of 14:12, 9 February 2021 by Ralphmm (Talk | contribs) (→CODA 3 and VME Readout Set Up Details)
Current Set Up for Running with Cosmics in TEDf (Feb 2021)
- 89 bars
- 2 CAEN v1190 TDCs (recording time information from all 180 channels)
- 2 v792 QDCs (recording charge information from subsets of 64 channels at a time)
- 12 NINO cards operating with AGILENT PSU and operating with internal threshold set by potentiometer on cards
- HV supplied by CAEN SY1527N main frame equipped with 1x A1531 primary PSU (have 3 spare) and 4x A1932A 48 channel HV distributer modules (have 4 spare)
CODA 3 and VME Readout Set Up Details
Details on ROC, PEB, and CODA3 setup etc to be added here:
- ROC
- Slot - 1
- Name -
- PEB
- Slot - 21
- Name -
- CODA Readout
- List file
- Location
- List file
- Crate
- Slot 1 - ROC
- Slot 2 - v1190
- Serial Number -
- Slot 3 - v1190
- Serial Number -
- Slot 4 - v792
- Serial Number -
- Slot 5 - v792
- Serial Number -
Running the DAQ and Analysis
- account is bbhodo on tedbbdaq machine (contact local users directly for password)
- To run coda:
- To run analysis scripts: