- Updates
- HCAL
- starting setting up overlapping clusters - will take cosmics next week to test
- Juan Carlos working on the library for the DAC
- Bryan updated FADC configuration libration ( issue setting up window correctly )
- studies amplifier saturation : saturates before the FADC
- HCAL
linear up to 3 V ( seems FADC at 2V is ok with attenuation )
- Bryan almost done with DVCS LED pulser - need VME address - Alex will send picture - Board is in slot 15
- HV Lecroy : need implement HV scripts to record the HV
- BB Shower
- setting up trigger monitor - list of what is needed
- NIM crate + 4x NIM ECL connector ( already there ) - 52 BNC cables from ESB
- setting up trigger monitor - list of what is needed
F1 TDC installed -
- Power supply for threshold : still need to load firmware
- FADCs : 4 from Brads will need to go to RP - 6 FADC on order - 2 from UMass -
- BB Hodoscope
- TDC noise issue making progress, issue resolved
- Blown fuse on LV not know why, replaced ADC signal back
- 5 v792 channels shift by 50 ADC values - issue with v792 looking for spare
- try implement Will display for hodoscope using tree - documentation ( ask Provokar )
- making ADC vs ToT plots
- Steve Wood working on getting
- BB GRINCH
- noise problem in repeater rack fixed
- raised threshold from 1.3 to 1.4 V , all noise gone
- working on GRINCH decoder and porting analysis software in SBS-online and in Podd - VETROC module being written
- GEM INFN
- will have check connection and change config files to remove
- GEM UVA
- HV scan being taken , CODA working ok
- GEM TEDF
- MPDs installed in crate for INFN , APV working , working on connection using MPDLibTest and i2ctest
- CDet
- All Nino installed, will start taking cosmics data soon
- CDet
- HV
- CAEN : managed through hodoscope , CAEN modules for GEN RP
- MPOD : managed through EPICs, need to check if will use CAEN NIM module ( MPOD should be sufficient )
- CAEN VME module for GEM - need EPICS or something for experiment ? Brad will help with ( need VME module and code used to use module )
- SSP zero suppression status : not used right now because testing, need to check with run with and without.
Scripts to generate Only UVA does not have current reference, could add additionnal noise - will need to check TEDF boards - jumpers for reference current might not be correct -
- VTP
- Need 3 VTPs for all the GEM ( each VTP can handle 80 modules )
- 2 VXS - will setup next week so ready for VTP testing