- Updates
- HCAL
- cable GUI installed on enpcamsonne, section 7.5 on wiki for documentation
- looking at cable length attenuation
- HCAL
globally
- gathering spool of cables and lemos to give to Wendy for 60 more cables for overlapping summing
- Chris agreed to make a patch panel for the DAC
- looking for the FADC being repaired
- maybe look into setting up external clock for F1
- Bigbite shower
- Issue with Fastbus getting stuck in weird state. Bryan has a temporary fix.
- 12 FADCs added, jumpers checked to be set to 2V and will start cabling
- Provokar more data for preshower calibration and will switch to FADC
- noise on one side of preshower, HV crate was replaced ( goes away when moving to other HV crate ) but still shifting pedestals on some channels, still need to look at signals with scope ( usually 5 mins runs ), might be ground loop - HV supposed to have same ground but need to check. Some channels have the shift on some channels with scope directly on PMT ( grounding near PMT did not help ), but disappear R26 when HV swapped to another HV card.
Schematics of bases of PMTs ? From Hermes not sure we have. Look with scope on HV too, see in Fastbus even with filter ( so higher frequency noise ).
- Bigbite hodoscope
- fix issues with analysis script - everything working
- more data taking
- Steve working on the TDC scaler using the hodoscope DAQ
- Bigbite hodoscope