September 10th 2021
From Hall A Wiki
- Updates
- Rate tests
- HCAL
- Progress new HV - was using amplitude - will use integral instead
- will start calibrating HV
- cosmics paddle setup on top, second paddle - under HCAL - will try to have cosmics trigger for calibration - can also get timing resolution
- will work on coincidence
- Bigbite Shower
- replaced module - signal consistent
- most FAN IN/OUT found in bad shape - only 3 good ones
- need FADCs for sums - will check with Chris
- FADC slot 6 replaced - broken given to Bill Gunning - tested but did not see - channel 7 of FADC
- Additionnal SD board for FADC from ED
- issues with F1 TDC at high rate, DMA errors, TI output about 20 ns, will switch to OT#2 so we can try larger gate
- Bryan check with Ed, width should be fine
- trigger from TDC output might be double pulsing - will switch to OT#2 - and put in scaler
- coincidence trigger BBCal and HCal -
- BigBite Hodoscope
- Good date at 4 different HV setting - need upper third
- pedestal fitting and can tune HV
- trigger on other detector for timing calibration
- need to use fast trigger , Ralph will check with Mark
- GRINCH
- OSP to access detector : 2 NINO cards replaced - fixed all empty channels mostly loose cables - 1 dead PMT - both ADC and TDC working
- trigger setup last night
- cosmics data - all ADCs cables - top 16 channel still weak - replaced with a spare
- setup ADC cables on front-end and long cosmics run
- CDet
- power outage test lab
- working on quality check on data
- Bigbite INFN GEM
- trying to fix noise issue - applying shielding to one INFN module - will take data to see if it is better - done on detector
- Bigbite UVA GEM
- running smoothly - data look normal - discrepancy between offline and online common mode
- XY and UV taking
- Scalers
- testing scalers on sbsvme29 SIS3800 and G0 scalers up to slot 10 - some not working -
Discriminator scaler working but mapping wrong -
- Beamline
- last check on BCM and VtoF, cleaning the fan out module, will do current test of unser
- still need to run cables -cable from green wall to SBS weldment - 25 cables
- LHRS
- 4 cables from LHRS to weldement
- connection to LHRS and TS
- HV
- RF
- plug in FADC ?
- can add F1 TDC -
- Helicity
- changes to be put in
- EDTM study ( Bob can help )
- Reference channel
- Beamline
- On going tasks
- Cable to weldment ( Jack ? )
- cabling scaler/beamline crate ( David , Bob 0%)
- HRS to TS and timing ( Bob, Maria 0% )
- EPICS / start End of run logging script (Alex, Bob 0% 09/15 )
- script check MPD sync ( Ben , Andrew )
- RF (Alex, Bob )
- sync check scripts ( Andrew , Alex )
- Hodoscope v1190 clock ( Alex , Mark , Ralph)
- check if calibration is needed after switch
- Full configration all crates ( Alex, Bryan )
- data rate test with new computer and 3 VTPs ( Alex, Bryan )
- test GEM zero supression ( Sean, Holly )- done
- GEM cosmics ( Sean, Holly )
- Shower cosmics (Arun, Provokar )
- HCAL cosmics (Scott)
- GRINCH cosmics ( Bradley )
- Hodoscope cosmics ( Ralph )
- DAQ documentation ( Alex, Rachel )
- suggest taking all detectors cosmics every night
- add scaler crate to full config
- coincidence trigger
- EDTM
- BB CAL and HCAL at TS - delayed after coincidence
- Issues
- Shower FADC bad channel - FADC replaced but problem could not be reproduce - need to test more
- HCAL ROC16 fiber - will double check if fiber 5 enabled - use slave5
- warning PEB ROC - Bryan checking with Dave - might incorrect flag -
- Shower F1 issue at high rate - need to check with OT#2 - check at sync event implemented - DMA error might come from multiple pulsing - might
- Status software in a-onl@aonl1
- GRINCH
- still need to install - need to check if commits were merged
- still running locally -
- Shower
- installed
- one script working with TS files
- GEM
- Andrew tried already
- Hodoscope
- installed
- HCAL
- setup and can look at data
- All crates
- Bigbite config : GEM GRINCH Hodoscope
- need add HCAL and HRS