Data Log
From Hall A Wiki
RUN # | Source/Cosmic/Pedestal | Source Position | Time | HV | # of events | notes |
---|---|---|---|---|---|---|
23 | S | lo x lo y | n/a | n/a | GEM 1 <-----PLOTS | |
24 | S | mid x lo y | n/a | n/a | ||
25 | S | hi x lo y | n/a | n/a | ||
26 | S | hi x mid y | n/a | n/a | ||
27 | S | hi x hi y | n/a | n/a | ||
28 | S | mid x mid y | n/a | n/a | ||
29 | C | n/a | 21 hrs | n/a | 72383 | ROC not responding |
35 | C | n/a | n/a | 3500 | ||
37 | C | n/a | n/a | 3550 | ||
38 | C | n/a | n/a | 3600 | ||
39 | C | n/a | n/a | 3650 | ||
40 | C | n/a | n/a | 3700 | ||
41 | C | n/a | n/a | 3750 | ||
42 | C | n/a | n/a | 3800 | ||
43 | C | n/a | n/a | 3600 | ||
44 | P | n/a | n/a | off | ||
45 | P | n/a | n/a | off | Ped reconfigured | |
46 | S | n/a | n/a | 3600 | 7863 | |
47 | C | n/a | n/a | 3600 | ||
51 | C | n/a | 24.5 hrs | 3600 | 20,000 | |
52 | P | n/a | n/a | off | 11,000 | |
53 | failed | |||||
54 | stopped early | |||||
55 | stopped early | |||||
56 | failed | |||||
57 | 3600 | |||||
58 | C | n/a | 5.2 hrs | 3600 | Client unresponsive | |
59 | S | n/a | n/a | 3600 | ||
60 | S | n/a | n/a | 3600 | ||
74 | S | n/a | n/a | 3700 | ||
75 | P | n/a | n/a | off | GEM # 3 | |
76 | failed | |||||
78 | P | n/a | n/a | off | new read out card | |
80 | C | n/a | n/a | 3700 | ||
81 | S | center | n/a | 3700 | ||
82 | S | center | n/a | 3700 | rate was abnormally high. Reset veto | |
83 | P | n/a | n/a | off | new LV distribution board | |
84 | S | center | n/a | 3700 | ||
85 | Test with VME Crate Transfer - GEM 2 | |||||
86 | "" | |||||
87 | "" | |||||
88 | "" | |||||
89 | "" | |||||
90 | "" | |||||
91 | "" | |||||
92 | "" | |||||
93 | "" | |||||
94 | "" | |||||
95 | "" | |||||
96 | P | |||||
97 | S | No HV - bad | ||||
98 | No Data recorded - Cause was found due to cards with same address | |||||
99 | P | |||||
100 | S | Center | 3700 | GEM 2 <----- PLOTS | ||
101 | S | Low X, Low Y | 3700 | Bad reading in Y | ||
102 | S | High X, High Y | 3700 | No Data recorded - ROC Froze | ||
103 | S | "" | "" | No Data recorded - ROC Froze | ||
104 | S | "" | "" | Reset ROC | ||
105 | S | High X, Low Y | 3700 | Bad reading in Y | ||
106 | S | High X, Mid Y | "" | Y Reading Fine | ||
107 | S | High X, Low-Mid y | "" | Y Reading Bad | ||
108 | P | Changed Y Card - Card was not connected | ||||
109 | P | |||||
110 | S | High X, Low-Mid Y | Y Reading Bad | |||
111 | ABORTED | |||||
112 | S | Center | Old readout Card - It is bad. | |||
113 | S | Center | ROC FROZE | |||
114 | Checked CH1 readout - Nothing | |||||
115 | Checked CH0 | |||||
116 | S | Mid X, High Y | Y reading Fine | |||
117 | P | GEM 3<----- PLOTS | ||||
118 | S | Center | 3700 | |||
119 | S | Low X, Low Y | "" | Y reading bad | ||
120 | S | High X, High Y | "" | Y Reading fine | ||
121 | P | Redid Ped Run | ||||
122 | S | High X, Low Y | 3700 | Y reading Bad | ||
123 | P | Switched Boards on GEM | ||||
124 | S | High X, Low Y | 3700 | Y reading Bad | ||
125 | Changed Amplifier Output to Slot 2 and messed with DC Voltage | |||||
126 | P | |||||
127 | S | High X, Low Y | 3700 | Y reading Bad | ||
128 | P | GEM 4 <----- PLOTS | ||||
129 | C | 3600 | BAD | |||
130 | S | Center | 3700 | |||
131 | S | Low X, Low Y | 3700 | Y Reading Bad | ||
132 | S | High X, Mid Y | 3700 | Y reading good | ||
133 | S | High X, Mid-Low Y | "" | Y reading Bad | ||
134 | S | "" | 3750 | Y reading Bad | ||
135 | S | High X, High Y | 3700 | Y reading good | ||
136 | S | High X, High Y | 3700 | Y reading Good, Higher up on Y | ||
162 | P | GEM 4. Amplification board 1 | ||||
163 | P | GEM 4. Amplification board 2, no difference w/ board 2 | ||||
164 | P | GEM 4. Amp board 1. changed T.gem.x1.detmap & T.gem.y1.detmap->slot_lo to 1 in database | ||||
165 | S | 3590 | bottom->GEM 4 (source). top->GEM2. 2.73mA | |||
166 | S | 3600 | GEM 4 | |||
167 | S | GEM4 | ||||
168 | P | cram.gem.crl T1 70->60 | ||||
169 | P | cramsTprog T1 60->80 | ||||
170 | P | T1 80->70
T | ||||
171 | P | no input connected. Test to see what problem is | ||||
172 | S | Low X, Low Y | 3700 | |||
173 | aborted | |||||
174 | sS | Low X, Low Y | 3700 | changed to channel 2 | ||
175 | P | replaced Y card and conector | ||||
176 | P | changed CRAM card | ||||
177 | S | Mid X, Mid Y | 3700 | |||
178 | P | GEM 2 | ||||
179 | C | 3600 | ||||
180 | changed T.gem.X1.detmap & T.gem.Y1.detmap ->slot_lo to 1 | |||||
181 | S | changed T.gem.X1.detmap & T.gem.Y1.detmap ->slot_lo to 2 (changed back) | ||||
182 | S | |||||
183 | changed T1 to 50 in CRL code for 551b | |||||
184 | P | (kaptons unpluged) | ||||
185 | P | |||||
186 | S | 3700 | Changed T1 from 50 to 40 in CRL code | |||
187 | S | 3700 | CRL code still changed to 40. Data is going to neg(-) input in 550 | |||
188 | P | Changed polarity of trigger. Hold -> no difference | ||||
189 | S | 3700 | ||||
190 | S | 3700 | Changed CRL T1->70 | |||
191 | 3700 | Changed CRL T1->60 | ||||
192 | ||||||
193 | Changed CRL T1-> 50. aborted | |||||
194 | gate generator to make trigger hold. T1->50 | |||||
195 | S | 3700 | T1 50 -> 30 | |||
196 | S | 3700 | T1 30 -> 20 | |||
197 | 3750 | T1 20 -> 70 | ||||
198 | Clear coming from gate generator | |||||
199 | P | |||||
200 | S | 3750 | ||||
201 | looking @ scope | |||||
202 | S | 3750 | ||||
203 | looking @ scope | |||||
204 | S | 3750 | ||||
205 | S | 3700 | T5 -> 23 in CRL | |||
206 | S | 3700 | T5 -> 13 in CRL | |||
207 | S | looking @ scope | ||||
208 | S | made clockwidth about 20-40ns wider | ||||
209 | S | looking @ scope | ||||
210 | S | 3700 | T5 -> 18. T2 -> 8 | |||
211 | looking @ scope | |||||
212 | S | 3700 | T5 -> 28 | |||
213 | S | 3700 | T5 -> 33 | |||
214 | S | 3700 | T5 -> 38 | |||
215 | S | 3700 | T3 -> 20. about 200/7000? | |||
216 | Junk | |||||
217 | 3800 | |||||
218 | S | Mid X, Mid Y | 3800 | 20 ADC software threshold. X-2600. Y-2200. 50 ADC X-630 Y-530 | ||
219 | S | 3800 | 10,000 evts | T1->80. 400 entries | ||
220 | S | 3800 | 15,000 evts | T1->60. 2000 entries | ||
221 | S | 3800 | 10,000 evts | T1->55. 2000 entries | ||
222 | S | 3800 | 10,000 evts | T1->50. 3000 entries | ||
223 | S | 3800 | 10,000 evts | T1->45. 3700 entries | ||
224 | S | 3800 | 10,000 evts | T1->40. 4500 entries | ||
225 | S | 3800 | 10,000 evts | T1->30. 6000 entries | ||
226 | S | 3800 | 10,000 evts | T1->10. 7500 entries | ||
227 | S | 3800 | 10,000 evts | T1->0. 8200 entries | ||
228 | S | 3800 | 27,700 evts | T1->0. 22000 entries. Took out the "T" in data cable | ||
229 | S | 3700 | 10,000 evts | T1->0. 5800 entries | ||
230 | S | 3730 | T1->0. 7000 entries | |||
231 | C | 3780 | 20,000 evts | T1->0 | ||
232 | P | 10,000 evts | ||||
233 | C | 3780 | 492,784 evts | |||
234 | P | NEW CHAMBER. adjustment in potentiameter | ||||
235 | P | 3,848 evts | new chamber | |||
236 | P | both chambers | ||||
237 | P | both chambers. Bad x/y1 | ||||
238 | P | both chambers | ||||
239 | P | both chambers. changed 550 card | ||||
240 | junk | |||||
241 | S (Sr 90) | Center | 3730 | 12,468 | x2y2 chamber | |
242 | S (Sr 90) | moved around entire GEM | 3730 | 12,352 | ||
243 | S (Sr 90) | moved around entire GEM | 3800 | 20,151 | ||
244 | C | 3800 | ||||
245 | P | 3 GEMS | ||||
251 | P | From 245 - fixing CRL Code | ||||
252 | P | 2,357 | 3 GEMS | |||
253 | S | Center | 3751.2 | 10,628 | ||
254 | S | Moving | 3750 | Low voltage off | ||
355 | S | Moving (every 2000 evts) | 3750 | 62,540 | ||
256 | C | |||||
261 | S | X1/Y1 | 3750 | 11,029 | Bad. Data in 1 and 3 reversed | |
262 | S | X1/Y1 | 3750 | 13,128 | ||
263 | S | X1/Y1 | 3750 | |||
264 | C | 8-2-10 6pm to 8-3-10 11am | 3750 | |||
265 | P | 3 GEMS | ||||
266 | C | 3751.2 | 3 GEMS | |||
267 | C | 3750 | 3 GEMS | |||
268 | C | 3750 | 3 GEMS. Scintillator distance ~ 2ft | |||
269 | Test | |||||
270 | C | Test w/ cosmics one scint, one GEM | ||||
271 | P | |||||
272 | 8-19-10 5pm to 8-20-10 11am | |||||
273 | P | NEW GEM STAND SETUP. 3 GEMS. Don't analyze | ||||
274 | P | Don't analyze | ||||
275 | P | |||||
276 | P | |||||
277 | P | |||||
278 | P | |||||
279 | P | Good ped run | ||||
280 | C | Preset evt limit - 5000 | ||||
281 | C | 8-21-10 5pm to 8-24-10 1pm | 3750 | 3 GEMS | ||
282 | C | Looking @ signal | ||||
283 | 3800 | 3 GEMS. Coincidence 1 | ||||
284 | 3800 | 3 GEMS. Coincidence 2 (Calorimeter & Scintillator) | ||||
285 | C | 8-26-10 5pm to 8-30-10 6pm | 3700 | 37,428 | 3 GEMS. | |
286 | 8-30-10 6pm to ? | 3650 | 3 GEMS | |||
NEW | NEW | NEW | NEW | NEW | NEW | START NEW GAS SETUP W/ 3 GEMS. GAS SPLIT 3 WAYS. FLOWS THROUGH EACH CHAMBER AND IS MONITORED WITH SEPARATE BUBBLER AT EACH OUTPUT |
287 | C | 9-1-10 6pm to 9-2-10 2pm | 3750 | Looks much better with new gas flow! | ||
288 | C | 9-2-10 6pm to 9-3-10 2pm | GEM 1 3800 GEM 2 3750 GEM 3 3750 | 9,400 | ||
289 | C | 9-3-10 1:30pm to 9-7-10 | GEM 1 3800 GEM 2 3750 GEM 3 3750 | |||
290 | C | 9-7-10 3:15pm to 9-8-10 12pm | GEM 1 3700 GEM 2 3725 GEM 3 3725 | 8,338 | Changed kapton and card for Y strips on GEM 2 | |
|