*VXS crates power supplies controls
+
[[BigBite_trigger_and_DAQ]]
**http://hcalvxs1.jlab.org HCAL bottom crate
+
 
 +
*VXS crates power supplies controls (open in browser on VNC)
 +
**http://129.57.192.243<s>http://hcalvxs1.jlab.org</s> HCAL bottom crate
 
**http://hcalvxs2.jlab.org HCAL top crate
 
**http://hcalvxs2.jlab.org HCAL top crate
 
**http://bbhodovxs.jlab.org hodoscope crate
 
**http://bbhodovxs.jlab.org hodoscope crate
**http://bbgemvxs.jlab.org  
+
**http://sbsgemcrate02.jlab.org SBS GEM crate 02 (sbsvtp2)
**http://sbsgemvxs1.jlab.org
+
**http://sbsgemcrate01.jlab.org SBS GEM crate 01 (sbsvtp2)
**http://hallavme12.jlab.org
+
**http://hallavme12.jlab.org BB GEM crate
 +
**http://grinchvxs.jlab.org GRINCH crate
 +
**http://lefthrsvxs.jlab.org HRS crate
 +
**http://bbshowervxs.jlab.org BB Shower VXS crate
  
 
*CAEN crate'
 
*CAEN crate'
 
**ssh sbs-onl@intelbbmpd
 
**ssh sbs-onl@intelbbmpd
 
**type minicom, if error do a "killall minicom" wait a minute and try again
 
**type minicom, if error do a "killall minicom" wait a minute and try again
 +
**tyoe CAEN
 +
**choose c
 +
**turn off and on the crate
 +
**exit from menu
  
  
Line 15: Line 24:
 
**http://hareboot6.jlab.org
 
**http://hareboot6.jlab.org
 
***INFN crate port 7
 
***INFN crate port 7
***UVA crate port 6
+
***BB UVA crate port 6
 
**http://hareboot32.jlab.org
 
**http://hareboot32.jlab.org
***UVA LV
+
***BB UVA GEM LV port 5
 
***Trigger distribution box
 
***Trigger distribution box
 +
**http://hareboot14.jlab.org
 +
***[https://sbs.jlab.org/wiki/index.php/GRINCH_Gas_Panel_Camera GRINCH gas panel camera switch 1]
 +
***[https://sbs.jlab.org/wiki/index.php/GRINCH_LED_Pulser GRINCH LED pulser switch 8]
 +
**[https://sbs.jlab.org/wiki/index.php/Remote_Power_Cycling Detailed Instructions on Power Cycling + hareboot14 Device List]
 +
**http://129.57.188.119
 +
***enpcamsonne PC port 4
 +
*** HCAL VTP 28 and 29 portserver port 5
 +
***HCal/BBCal Threshold Readback rpi port 8
 +
**http://prexreboot01.jlab.org
 +
***SBS MPD crate0 (sbsvme32) port 1
 +
***SBS MPD crate1 (sbsvme30) port 2
 +
**http://prexreboot02.jlab.org
 +
***SBS MPD crate2 (sbsvme25) port 1
 +
***SBS UVA Inline GEM LV port 2
 +
***Port 3-7 Fan In/Out modules
  
 
*Portservers
 
*Portservers
Line 24: Line 48:
 
***port 3 sbsvtp1
 
***port 3 sbsvtp1
 
***port 4 sbsvtp3
 
***port 4 sbsvtp3
 +
 +
*INFN GEM LV
 +
**The INFN low voltage is accessible by browser.  This low voltage control has two channels: channel 1 controlslayer J0,  and channel 2 controls layer J2.  The operation manual for the low voltage power supply,  whichincludes a remote control command list, can be found:  CPX400DP.The following instructions can be usedto access the INFN low voltage power supply:1.  Open a firefox browser (from network)2.  In address bar, type:  129.57.188.51 (for BigBite LV supply)3.  Click on Instrument Control4.  TypeOPALL 0to turn off.  TypeOPALL 1to turn on
 +
 +
*Power cycle Scaler crate intelha9 (vme: sbsvme29)
 +
  /adaqfs/home/sbs-onl/bin/caen_power.py
 +
from any computer logged as sbs-onl
 +
  caen_power.py intelha9 0 # turn off
 +
  caen_power.py intelha9 1 # turn on
 +
 +
Do the turn on line until you see Status 513 ( 512 is still off it seems )

Latest revision as of 03:20, 10 March 2023

BigBite_trigger_and_DAQ

  • CAEN crate'
    • ssh sbs-onl@intelbbmpd
    • type minicom, if error do a "killall minicom" wait a minute and try again
    • tyoe CAEN
    • choose c
    • turn off and on the crate
    • exit from menu


  • Portservers
    • bbps1
      • port 3 sbsvtp1
      • port 4 sbsvtp3
  • INFN GEM LV
    • The INFN low voltage is accessible by browser. This low voltage control has two channels: channel 1 controlslayer J0, and channel 2 controls layer J2. The operation manual for the low voltage power supply, whichincludes a remote control command list, can be found: CPX400DP.The following instructions can be usedto access the INFN low voltage power supply:1. Open a firefox browser (from network)2. In address bar, type: 129.57.188.51 (for BigBite LV supply)3. Click on Instrument Control4. TypeOPALL 0to turn off. TypeOPALL 1to turn on
  • Power cycle Scaler crate intelha9 (vme: sbsvme29)
 /adaqfs/home/sbs-onl/bin/caen_power.py

from any computer logged as sbs-onl

 caen_power.py intelha9 0 # turn off
 caen_power.py intelha9 1 # turn on

Do the turn on line until you see Status 513 ( 512 is still off it seems )