== Priority Items ==
 
== Priority Items ==
  
<s>Jumper bars for SBB coils </s> Done.
+
Replace PLC relay card on SHMS Dipole - spare card is on the 2nd floor
  
Controls for SBB and corrector coils (waiting for water to the magnets, software updates)
+
Install 230V -> 115V transformers for +/-15V supplies dying in Hall C Danfysik supplies - transformers ordered
 
+
<s>Install magnet leads for SBB (535 MCM cable)</s> Done.
+
 
+
<s>Connect magnet leads for SBB corrector magnets </s> Done.
+
  
 
Readout for LCW pressure sensors added at end of beamline walkway (not started)
 
Readout for LCW pressure sensors added at end of beamline walkway (not started)
  
Re-install crash buttons in Hall A Counting Room - RQ1 button for BB and new ones for SBS supply and correctors (Done, BB and SBS need tested, correctors work)
+
Replace air compressor in Hall A Gas Shed - ordered - need to remove old compressor and dryer.
  
<s>Install thermistors on SBS/Big Bite magnets and junction boxes.</s> Done.
+
Gas manifolds for GEM gas cylinders (started)
  
<s>Install Klixons on SBB.</s> Done.
+
Nitrogen supply for GEM gas cylinder valves (Clippard valves and cylinder controller) (not started)
  
Mount Left Shield House temperature readout in CH
+
Gas mix controller and MFCs for GEM detectors (not started)
  
Find video cables from hall in the CH
+
Add "T's" and pump out ports to HMS magnet vacuum gauge ports.-Steve didn't want work done.
  
Measure current on 12V supplies in HMS magnet supplies when hall C is open long enough
+
Move ozone meters from VME to PI.
  
 
== Would Be Good To Do Items ==
 
== Would Be Good To Do Items ==
 
Re-locate NDX detectors in Hall A - one in DAQ bunker and the other in BB GEM bunker
 
 
Test LQ2 FuG with new polarity reversal switch.
 
 
Find and connect NMR cables in CH
 
 
Gas manifolds for GEM gas cylinders (started)
 
 
Nitrogen supply for GEM gas cylinder valves (Clippard valves and cylinder controller) (not started)
 
 
Gas mix controller and MFCs for GEM detectors (not started)
 
 
Roofing material for SBS GEM bunker (located some possible material - will run past Jessie)
 
  
 
Remove actuators from right arm magnets. (Dipole/Q3 complete)
 
Remove actuators from right arm magnets. (Dipole/Q3 complete)
Line 45: Line 27:
 
clean up L-arm supply platform
 
clean up L-arm supply platform
  
Swap out MFCs in VDC mixing system
+
Build new controller for testing and calibration warm return valves for Hall C
  
HMS/SHMS Heater and fan changes, fixes, upgrades etc.
+
Build local valve control boxes with local read out.
  
== PARTS ORDER LIST FOR 1 OCT ==
+
op check/repair hall C vacuum gauges.
  
-2 wire cable,
+
Re-route the Danfysik extension cables inside the HMS hut - get the excess off the floor
ferrules,
+
 
\# 6 hardware
+
Cut and install poly shielding around HVAC controls on the Right HRS
 +
 
 +
== Do We Still Need To Do These? ==
  
 
== Possible Future Items ==
 
== Possible Future Items ==
 
Replace air compressor in Hall A Gas Shed (on hold till next fiscal year)
 
  
 
Remote reset for Hall C spectrometer motion (maybe next year)
 
Remote reset for Hall C spectrometer motion (maybe next year)
 
Install new liquid level meters on SHMS- Install done, waiting on software and LN2 probe cal to go live (need Steven).
 

Revision as of 12:18, 12 August 2022

Priority Items

Replace PLC relay card on SHMS Dipole - spare card is on the 2nd floor

Install 230V -> 115V transformers for +/-15V supplies dying in Hall C Danfysik supplies - transformers ordered

Readout for LCW pressure sensors added at end of beamline walkway (not started)

Replace air compressor in Hall A Gas Shed - ordered - need to remove old compressor and dryer.

Gas manifolds for GEM gas cylinders (started)

Nitrogen supply for GEM gas cylinder valves (Clippard valves and cylinder controller) (not started)

Gas mix controller and MFCs for GEM detectors (not started)

Add "T's" and pump out ports to HMS magnet vacuum gauge ports.-Steve didn't want work done.

Move ozone meters from VME to PI.

Would Be Good To Do Items

Remove actuators from right arm magnets. (Dipole/Q3 complete)

clean up R-arm supply platform

clean up L-arm supply platform

Build new controller for testing and calibration warm return valves for Hall C

Build local valve control boxes with local read out.

op check/repair hall C vacuum gauges.

Re-route the Danfysik extension cables inside the HMS hut - get the excess off the floor

Cut and install poly shielding around HVAC controls on the Right HRS

Do We Still Need To Do These?

Possible Future Items

Remote reset for Hall C spectrometer motion (maybe next year)