Difference between revisions of "How to adjust discriminator threshold on HCAL DAC"

From Hall A Wiki
Jump to: navigation, search
Line 9: Line 9:
 
*After executing the command, the a new DAC gui should pop up which has instructions to load, initialize and save the settings and adjust the thresholds.  
 
*After executing the command, the a new DAC gui should pop up which has instructions to load, initialize and save the settings and adjust the thresholds.  
 
* Click on "Load mpv04Library tab" to load a library
 
* Click on "Load mpv04Library tab" to load a library
* Click on "Initialize mpv04"
+
* Click on "Initialize mpv04" to initialize the library
*Click on "Save settings"
+
*Click on "Save settings" to save the settings
 
*Go to the "Enter New Voltage Setting (Volts)" slot and enter the desired threshold
 
*Go to the "Enter New Voltage Setting (Volts)" slot and enter the desired threshold
 
* Click on "Set Voltage" after entering the desired threshold.
 
* Click on "Set Voltage" after entering the desired threshold.
 
*Make sure that BBCal Hi Discriminator 1 and BBCal Hi Discriminator 2 have the same value entered
 
*Make sure that BBCal Hi Discriminator 1 and BBCal Hi Discriminator 2 have the same value entered
 
* Check the online gui on to make sure that the entered thresholds are indeed registered.
 
* Check the online gui on to make sure that the entered thresholds are indeed registered.

Revision as of 15:42, 27 September 2021

return to Shift How-To

How to adjust th VME DAC BBCAL thresholds

  • Log into daq@enpcamsonne
    • ssh daq@enpcamsonne
  • Go to test_fadc
  • Execute the command python3 DAC_Control_GUI.py
  • After executing the command, the a new DAC gui should pop up which has instructions to load, initialize and save the settings and adjust the thresholds.
  • Click on "Load mpv04Library tab" to load a library
  • Click on "Initialize mpv04" to initialize the library
  • Click on "Save settings" to save the settings
  • Go to the "Enter New Voltage Setting (Volts)" slot and enter the desired threshold
  • Click on "Set Voltage" after entering the desired threshold.
  • Make sure that BBCal Hi Discriminator 1 and BBCal Hi Discriminator 2 have the same value entered
  • Check the online gui on to make sure that the entered thresholds are indeed registered.