Difference between revisions of "January 14th 2022"

From Hall A Wiki
Jump to: navigation, search
(Created page with "*Updates **HCAL **BB Cal **Hodoscope **GRINCH **CDet **GEM BB **GEM INFN **GEM GEN RP **beamline **helicity *Issue **HCAL LED **GEM latency different for different places in...")
 
 
Line 1: Line 1:
 
*Updates
 
*Updates
 
**HCAL
 
**HCAL
 +
**issue with VETO and LED produced jitter on gate generator, took this part of VETO out, redid signal from pulser output with delay, signal looks good now
 +
***veto should still be working, if not can use software cut
 +
***pulser trigger was sent to F1 but was removed ( F1 overflow ? )
 +
***beam data : Sebastian replaying all data, everything looked ok on HCAL with beam ( besides LED )
 +
***timing of T2 different for T1 - Cosmics have different latency - should be fine with beam
 
**BB Cal
 
**BB Cal
 +
***4.5 and 4.6 were checked by Provokar ( good cosmics signal - but less efficient with beam ) - need to be investigated
 +
***data looked ok
 
**Hodoscope
 
**Hodoscope
 +
***hodoscope was turned on, data looked ok
 +
***checking with Steve with EPICS
 
**GRINCH
 
**GRINCH
 +
***beam data looks good, some missing channels,
 +
***hodoscope have additionnal spare NINO, some fixed were shipped
 
**CDet
 
**CDet
 +
***plan to test other half detector
 
**GEM BB
 
**GEM BB
 +
***latency difference between
 
**GEM INFN
 
**GEM INFN
 
**GEM GEN RP
 
**GEM GEN RP
 
**beamline
 
**beamline
 +
***Hall BCM average was different from MPS : David will reset the calibration value, raster calibration
 
**helicity
 
**helicity
 +
***David and Paul going back to analysis of helicity, several branches created but some branches not filled up yet, looking into it
 +
**scripts
 +
***Bob deployed jmirror which should be faster, being used in Hall B and D - seems to work - halog with details
 +
  
 
*Issue
 
*Issue
**HCAL LED
+
**HCAL LED jitter : fixed
 
**GEM latency different for different places in detector
 
**GEM latency different for different places in detector
 
*To do
 
**
 

Latest revision as of 11:51, 14 January 2022

  • Updates
    • HCAL
    • issue with VETO and LED produced jitter on gate generator, took this part of VETO out, redid signal from pulser output with delay, signal looks good now
      • veto should still be working, if not can use software cut
      • pulser trigger was sent to F1 but was removed ( F1 overflow ? )
      • beam data : Sebastian replaying all data, everything looked ok on HCAL with beam ( besides LED )
      • timing of T2 different for T1 - Cosmics have different latency - should be fine with beam
    • BB Cal
      • 4.5 and 4.6 were checked by Provokar ( good cosmics signal - but less efficient with beam ) - need to be investigated
      • data looked ok
    • Hodoscope
      • hodoscope was turned on, data looked ok
      • checking with Steve with EPICS
    • GRINCH
      • beam data looks good, some missing channels,
      • hodoscope have additionnal spare NINO, some fixed were shipped
    • CDet
      • plan to test other half detector
    • GEM BB
      • latency difference between
    • GEM INFN
    • GEM GEN RP
    • beamline
      • Hall BCM average was different from MPS : David will reset the calibration value, raster calibration
    • helicity
      • David and Paul going back to analysis of helicity, several branches created but some branches not filled up yet, looking into it
    • scripts
      • Bob deployed jmirror which should be faster, being used in Hall B and D - seems to work - halog with details


  • Issue
    • HCAL LED jitter : fixed
    • GEM latency different for different places in detector