Line 44: Line 44:
 
147 PMT1,2,3 No LED,  use small LV cable with ground cable
 
147 PMT1,2,3 No LED,  use small LV cable with ground cable
 
148 PMT1,2,3 No LED,  HV changed from "HV98fc-850V" to "HV147fc-900V"
 
148 PMT1,2,3 No LED,  HV changed from "HV98fc-850V" to "HV147fc-900V"
 +
149 PMT1,2,3 No LED, Rate 100 Hz (interval 10 ms), HV changed from "HV98fc-850V" to "HV147fc-900V"
  
 
</pre>
 
</pre>

Revision as of 12:09, 5 October 2020

 
HV 98fc_850V
all threshold 230, all gain 64
LED 4.4V 9.38ns 10Hz
ch 16 is trigger

run	note
67	PMT1,2,3 	
69	PMT1,2,3 	change SSP_RICH_W_WIDTH from 400 to 2000
70	PMT4,5,6
72	PMT4,5,6	change SSP_RICH_W_WIDTH from 2000 to 400
73	PMT7,8,9 
74	PMT10,11,12
75	PMT13,14,15
76	PMT1,2,3	LED change from 4.4V to 3.5V
77	PMT1,2,3	LED change to 4.0V
78	PMT1,2,3	LED change to 4.3V
80	PMT1,2,3	LED change to 5.0V
81	PMT1,2,3	LED change to 4.4V	15k events
82	PMT1,2,3	LED change to 4.4V	33k events
84	PMT1,2,3	change from ssp.cnf_thr230_gain64 to ssp.cnf_thrHV98fC850V_gainmap
86	PMT1,2,3	change from small to big LV cable
87	PMT1,2,3	
88	PMT1,2,3	
91	PMT1,2,3	add grounding wire
92	PMT7,2,3
94	PMT1,2,3	FADC250_CH_DAC from 500 to 600 for quad of PMT2,3
95	PMT1,2,3	FADC250_CH_DAC from 600 to 400 for quad of PMT2,3
98	PMT1,2,3	FADC250_CH_DAC from 500 to 300 for quad of PMT1
100	PMT1,2,3	FADC250_CH_DAC from 400 to 1000 for quad of PMT2,3
104	PMT1,2,3	FADC250_CH_DAC from 400 to 1000 for quad of PMT2,3
106	PMT1,2,3	
131	PMT1,2,3	moved from ESB to testlab, FADC250_CH_DAC quad 500 and sum 3000, use small LV cable with ground cable, board 7 and fiber 4 has no LV
132	PMT1,2,3	28k events
133	PMT1,2,3	use small LV cable without ground cable
134	PMT1,2,3	use small LV cable with ground cable
139	PMT1,2,3	LED change to 4.42V, use small LV cable with ground cable
140	PMT1,2,3	LED change to 4.45V, use small LV cable with ground cable
141	PMT1,2,3	LED change to 4.48V, use small LV cable with ground cable
142	PMT1,2,3	LED change to 4.52V, use small LV cable with ground cable
143	PMT1,2,3	LED change to 4.56V, use small LV cable with ground cable
144	PMT1,2,3	LED change to 4.60V, use small LV cable with ground cable
145	PMT1,2,3	LED change to 4.65V, use small LV cable with ground cable
147	PMT1,2,3	No LED,  use small LV cable with ground cable
148	PMT1,2,3	No LED,  HV changed from "HV98fc-850V" to "HV147fc-900V"
149	PMT1,2,3	No LED, Rate 100 Hz (interval 10 ms), HV changed from "HV98fc-850V" to "HV147fc-900V"