Post Beam Checklist for an Extended Time

                                                                Last revised 2/22/99

This checklist will be completed prior to extended restricted accesses to Hall A.

 

People checking list _______________________________________________________

 

  Power supplies

                        ( from the control room )

Electron

Q1

___     set current to 0 amps by remote control

___     turn output off by remote control

 

Q2

___     set current to 0 amps by remote control

___     turn output off by remote control

 

Q3

___     set current to 0 amps by remote control

___     turn output off by remote control

 

Dipole

___     set current to 0 amps by remote control

___     turn output off by remote control

 

Hadron

Q1

___     set current to 0 amps by remote control

___     turn output off by remote control

 

Q2

___     set current to 0 amps by remote control

___     turn output off by remote control

 

Q3

___     set current to 0 amps by remote control

___     turn output off by remote control

 

Dipole

___     set current to 0 amps by remote control  

                                ( from the Hall )

Target

 

___     NOTE :  LOOK FOR "RADIATION AREA" SIGN and OBEY

 

___     Install protective shields over vacuum windows if Cryo target is installed

___      target light off at target

___     cctv cameras off at target

___     turbo off at rack #

___     turbo valve closed at rack #                          switch #

___     backing pump off and bled up  at pump

___     gages operational

___     windows functional

 

 Spectrometers

 

___     NOTE :  LOOK FOR "RADIATION AREA" SIGN and OBEY

 

___     turbo valves closed at valve controller in rack # 1H71/72B08 switch #

___     turbo off at turbo controller in rack # 1H71/72B08

___     blower off at controls under spectrometer

___     pump valves closed at valve controller in rack # 1H71/72B08  switch #

___     convectron gages on

___     cold cathode gages off at gage in rack #

___     windows functional

Electron

Q1

___     ensure 0 current status on local power meter

___      ensure that the set to and ADC readouts all equal "0"

___     turn off  Q1 LCW supply valve slowly and lock it in the off position

 

Q2

___     ensure 0 current status on local power meter

___     ensure that the set to volts readout equals "0"

___     ensure that the set to current readout equals "0"

___     switch off input power at power supply

___     switch off power at safety disconnect and lock switch in the off position

 

Q3

___      ensure 0 current status on local power meter

___     ensure that the set to volts readout equals "0"

___     ensure that the set to current readout equals "0"

___     switch off input power at power supply

___     switch off power at safety disconnect and lock switch in the off position

 

Dipole

___     ensure 0 current status on local power meter

___     switch off input power at power supply

___     switch off power at safety disconnect and lock switch in the off position

   Hadron

Q1

___     ensure 0 current status on local power meter

___      ensure that the set to and ADC readouts all equal "0"

___     turn off  Q1 LCW supply valve slowly and lock it in the off position

 

Q2

___     ensure 0 current status on local power meter

___     ensure that the set to volts readout equals "0"

___     ensure that the set to current readout equals "0"

___     switch off input power at power supply

___     switch off power at safety disconnect and lock switch in the off position

 

Q3

___      ensure 0 current status on local power meter

___     ensure that the set to volts readout equals "0"

___     ensure that the set to current readout equals "0"

___     switch off input power at power supply

___     switch off power at safety disconnect and lock switch in the off position

 

Dipole

___     ensure 0 current status on local power meter

___     switch off input power at power supply

___     switch off power at safety disconnect and lock switch in the off position

  

 

Entrance beam tube

___     NOTE :  LOOK FOR "RADIATION AREA" SIGN and OBEY

 

___     beam line vacuum valves closed

___     E P turbo valve closed

___     E P turbo off

___     E P backing pump off and vented to atm.

___     Møller turbo valve closed

___     Møller turbo off

___     Møller backing pump off and vented to atm.

___     instrument air compressor functioning normally

 

 

                

Exit beam tube

___     NOTE :  LOOK FOR "RADIATION AREA" SIGN and OBEY

 

___     beam tube valve closed

___     exit beam tube turbo valve closed

___     exit beam tube turbo off

___     exit beam tube backing pump off and vented to atm.

___     cold cathode gage off

___     convectron gages on

         Dump

___     NOTE :  LOOK FOR "RADIATION AREA" SIGN and OBEY

 

___     turn off diffuser cooler

___     Inspect visible areas for water leaks

     Hall

___     NOTE :  LOOK FOR "RADIATION AREA" SIGN and OBEY

 

___     Inspect power supply platforms, spectrometers, and the rest of the Hall, looking for water leaks and cryogenic plumes

___      cctv cameras off

___     clear of unnecessary equipment

___     Man lift and Forklift removed from truck ramp

___     Doors unlocked

 

 