Next: General Description
Up: Hall A Polarized He
Previous: Contents
  Contents
- Overview of the target setup. Shown are the laser hut, the
beam pipes covering the laser beam line extending to the target area,
and the Helmholtz coils with the RF assembly and support sub-assembly.
- A topview of the laser hut shows the location
of the interlocked door as well as the position of the laser table where
all lasers and optics will be set up.
- Top view of the optics setup inside the laser hut. All items
are on a laser table
which is sitting on a mezzanine inside the laser hut
- Adjusting back-scattering light
- Typical 40 cm polarized He target cell used in this
experiment.
- Schematic diagram of the target ladder and target positions.
- Schematic diagram of the target cell oven control system. The
instruments in the dashed box are located upstairs, while the remaining
components are located in the Hall in the vicinity of the target.
For clarity, the interlock circuitry
is not shown (see Figure ).
- Schematic diagram of the oven heater interlock system.
The switches represent relays.
In normal operation, the relays are energized (contacts closed).
An alarm condition
(or instrument power failure) will de-energize (open)
the corresponding relays, interrupting the interlock circuit.
The instruments are programmed such that their dual alarm outputs
operate simultaneously.
- Top view of the longitudinal and transverse Helmholtz coils
used in the polarized He target setup.
The RF coils are needed to perform NMR as well as EPR measurements. The
0 angle gives the incident electron
beam direction. The
dashed lines indicate the coils main axis, the long bold
arrow indicates the holding field direction which can be
rotated from 0
to 360. We also show the laser beam
longitudinal and transverse directions.
- The electronics is located in
the Counting House A.
- Description of the cabling of the NMR system.
10 cables go from the counting house to the target location
in the hall : 8 (main+sensing) ESSEX AWG 10 for
the Helmholtz coils, 1 RG58A/U for the RF coils and 1 RG58A/U for the
pick-up coils.
- Circuit for EPR lineshape measurement
- Circuit for EPR measurement with AFP spin flip
- Circuit for continuous EPR measurement with field feedback
- Schematic of reference cell system
- Valve configuration of the reference cell gas system
- Control panel
- Optical Setup in the Laser Hut
- The Polarized He Target Laser Hut Setup
Xiaochao Zheng
2001-06-01