• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT
    Make New Entry, Make Followup Entry

    User name R. Michaels

    Log entry time 11:07:45 on February 13, 2011

    Entry number 346654

    This entry is a followup to: 346650

    keyword=TS0 no problem

    TS0 is not part of the datastream except that the scalers are inserted
    asynchronously every ~4 sec as event type 140.  The reason it is part 
    of the CODA config is to allow clearing of scalers and final read during
    the state transitions start/end.  
    
    The same would be true for L-HRS TS11, except that one contains helicity
    info, which is vital to deuterium.  Hence, TS11 had to be part of the
    datastream.  Generally you don't add a crate to a datastream unless
    you have to.
    
    Everything is fine ... but you still need to check the data to be sure.