(Note: All Counters start with '0' but not '1') 1, S1-1L, 1R are noisy, which are an old issue since I found that the PMTs are very noisy. It has been conformed that they are not because of light-leak. 2, S2m-13R has wide pedestal. I will check the connection once the hall is open again. Or we should try to reduce its HV. 3, PRL1: 9,17,18,19,20,32 have only pedestals. 21 is very noisy. PRL2: 3 has lower statistic. 15,16,32,33 are empty (those four channels are in the same ADC connection, so I am pretty sure that it is disconnected. I will fix it when the hall is open) 4, Cerenkov is not in use currently so all HVs are all. Summary: Only PRL1/2 have some empty channels, which are hard to trace because the Map is complicate. I need people who needs better on PRL to help.
S1 ADC
S1 TDC
S2 ADC 1
S2 ADC 2
S2 ADC 3
S2 TDC 1
S2 TDC 2
S2 TDC 3
VDC Wires
VDC Time
VDC Hits
VDC Effic
PRL1 ADC 1
PRL1 ADC 2
PRL1 ADC 3
PRL2 ADC 1
PRL2 ADC 2
PRL2 ADC 3