Main INDEX
Monthly INDEX
PREV
NEXT
User name Armstrong
Log entry time 23:41:37 on June24,2001
Entry number 64472
This entry is a followup to: 64429
Followups:
keyword=beam oscillations gone?
The oscillations in beam intensity and the correlated oscillations in charge
asymmetry noted in halog entry 64429 extend back in time at least as far
as parity run 017 (June 23 16:44) which is as far back as I have checked.
Thus they have been around for > 24 hours.
However, they have disappeared again this evening, around 21:00; the
last two runs (943 and 944) do not show the oscillations !
I call MCC and enquire if they are doing anything differently, and they
say no. They are running with FastFeedback on, but with the Energy
locks OFF; that has been since about 19:00, so it does not appear to
correlated with the improved beam stability that we see. Wish I knew
what they are doing differently!
FIGURE 1