Main INDEX
Monthly INDEX
PREV
NEXT
User name M. Rvachev
Log entry time 05:49:30 on June26,2001
Entry number 64651
This entry is a followup to: 64608
keyword=Beam charge asymmetry oscillations
At appr. 4:15am beam charge asymmetry started sinusoidal fluctuations with
amplitude ~700ppm, mean value of 400ppm and period ~60 minutes. From 0:00am
to 4:15am asymmetry was small. It seems that yesterday's pattern repeats as if
fluctuations are correlated to time of day. MCC says nothing has been changed in
setup during the night and they don't know what can stop them.
A parity log entry # 22646 from July 15,1999 links period of current fluctuations
to "frequency of the compressor", the original is at
http://hallaweb.jlab.org/parity/log/html/9907_archive/990715073808.html
also the text is pasted below.
User name M.Baylac
Log entry time 07:38:08 on July 15,1999
Entry number 22646
keyword=Current oscillations time constant
Time constant of current oscillations changed after injector people changed the frequency of the compressor :
it is now ~ 11 minutes
FIGURE 1