• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name Rikki

    Log entry time 15:02:15 on January27,2004

    Entry number 116905

    Followups:

    keyword=day shift summary

    08:00 run #2178 in progress
    08:12 begin multi-harp scan
    08:44 multi-harp scan results
    1C12
    x sig: 0.2371 +/- 0.0173
    Seems a little wide in x but according to Mauro, there's not much MCC can do because if they make it narrower, the ion chambers will trip. After the access to cool the magnet, we'll do another scan.
    08:45 asked for access to cool left septum
    11:30 everyone is out of the hall - asked for beam
    11:55 multi-wire harp scan results:
    1C12
    x sig: 0.1624 +/- 0.0109
    1H03A
    x sig: 0.1186 +/- 0.0097
    y sig: 0.0750 +/- 0.0194
    1H03B
    x sig: 0.072 +/- 0.0078
    y sig: 0.0203 +/- 0.0333
    12:02 begin #2188
    12:08 turns out septum got stuck at 60 Amps. Ramping up to 183.5 Amps.
    12:35 begin #2189
    12:42 begin #2190
    13:19 move to Waterfall target
    13:27 begin #2191
    14:16 begin #2192
    14:19 MCC sending pulsed beam, fast feedback problems
    14:

    run summary
    -----------------
    #2178 12C 07:49-08:12 485k
    #2179-2188 JUNK
    #2189 12C 12:36-12:40 36k - getting ps factors
    #2190 12C 12:42-13:12 752k
    #2191 H2O 13:27-14:13 753k
    #2192 JUNK