Main INDEX
Monthly INDEX
PREV
NEXT
User name Rikki
Log entry time 15:02:15 on January27,2004
Entry number 116905
Followups:
keyword=day shift summary
08:00 run #2178 in progress
08:12 begin multi-harp scan
08:44 multi-harp scan results
1C12
x sig: 0.2371 +/- 0.0173
Seems a little wide in x but according to Mauro, there's not much MCC can do because if they make it narrower, the ion chambers will trip. After the access to cool the magnet, we'll do another scan.
08:45 asked for access to cool left septum
11:30 everyone is out of the hall - asked for beam
11:55 multi-wire harp scan results:
1C12
x sig: 0.1624 +/- 0.0109
1H03A
x sig: 0.1186 +/- 0.0097
y sig: 0.0750 +/- 0.0194
1H03B
x sig: 0.072 +/- 0.0078
y sig: 0.0203 +/- 0.0333
12:02 begin #2188
12:08 turns out septum got stuck at 60 Amps. Ramping up to 183.5 Amps.
12:35 begin #2189
12:42 begin #2190
13:19 move to Waterfall target
13:27 begin #2191
14:16 begin #2192
14:19 MCC sending pulsed beam, fast feedback problems
14:
run summary
-----------------
#2178 12C 07:49-08:12 485k
#2179-2188 JUNK
#2189 12C 12:36-12:40 36k - getting ps factors
#2190 12C 12:42-13:12 752k
#2191 H2O 13:27-14:13 753k
#2192 JUNK