User name R. Michaels
Log entry time 00:31:07 on October14,2005
Entry number 156765
Followups:
keyword=wrong septum set points
The septum set points scaled by momentum (see HOWTO page)
should be 294(L) and 288(R). So, they are both 10% high at
the moment. I realize we ran Helium with R-arm exceptional at 10%
high but I believe L-arm was nominal. In any case, we'll need to
adjust these and decide what is best to run as soon as possible.
We will continue with "wrong" (+10%) values for now.
I believe the decision tree is:
1. Adjust septum, see what it does to septum cooling. Probably
not relevant for Left arm (not limited there) which is why we had
left it at 0% during Helium.
2. See what septum does to rates in detectors, taking care to
optimize alignment for each septum setting.
3. Converge and decide in a reasonable time. Get to production.