    User name D. Parno

    Log entry time 22:20:04 on January29,2008

    Entry number 227957

    Followups:

    keyword=FADC Accumulators

    Accumulator histograms for a 50,000 event integration mode run with DAC offset 
    set to minimize accdiff. Run number = #60317.
    
    Fig. 1: Histograms of Entire Accumulators
    Fig. 2: Blue histogram = accumulator values with laser cavity on. Black 
    histogram = accumulator values with laser cavity off.
    
    A reminder of what each accumulator means. Thr1 is near pedestal, Thr2 is 
    cutoff for big pulses.
    
    acc1: Integrate everything; no thresholds.
    
    acc2: Integrate everything above Thr1 (near pedestal)
    
    acc3: Integrate everything between Thr1 and Thr2 (Compton events).
    
    acc4: Integrate everything below Thr2 (big pulses)
    
    acc5: Integrate everything below Thr1 (plus some number of pulses to get the 
    tails) that is not included in acc6.
    
    acc6: Integrate everything below Thr2, plus some number of pulses to get the 
    tails.
    
    For this run, Thr1 was set at 1925 and Thr2 at 930.
    


    FIGURE 1