    keyword=PVDIS R-HRS Cerenkov

    For PVDIS parasites only ...

    In my list of detector issues I forgot to mention Cerenkov.
    The status is show in fig 1 for run 20220 taken tonight at
    P0=0.2 GeV the currently favored setting on R-HRS.

    There are clearly very few, if any, electrons. (I think the
    expected rate was 10^-3 Hz). The PMTs labeled 2,3, and 6
    below seem to be only pedestal, so maybe there's a problem with
    those PMTs or cables. I think we'll need at least a few Hz of
    electrons spread across the focal plane to tune up the detectors,
    i.e. to set and match gains.

    1-pass quasielastic might be best. My rough estimate is the
    rates may be a few Hz (needs to be checked). Also QE tends to
    fill the focal plane, which we need.

    I'll let run 20220 go several hours, though it's of dubious value.