Main INDEX
Monthly INDEX
PREV
NEXT
Make New Entry,
Make Followup Entry
User name R. Michaels
Log entry time 21:20:19 on August22,2009
Entry number 285209
Followups:
keyword=HRS DAQ ROC2 problems.
ROC 2 spits out things like below.
Result is that CODA crashes.
I'm trying some things to fix this. It's a new problem.
0x1bbdd00 (tNetTask): dc0 - restarting device.
interrupt: dc0 - fatal DMA underflow
0x1bbdd00 (tNetTask): dc0 - restarting device.
interrupt: dc0 - fatal DMA underflow
0x1bbdd00 (tNetTask): dc0 - restarting device.
interrupt: dc0 - fatal DMA underflow
0x1bbdd00 (tNetTask): dc0 - restarting device.
interrupt: dc0 - fatal DMA underflow
0x1bbdd00 (tNetTask): dc0 - restarting device.
interrupt: dc0 - fatal DMA underflow
0x1bbdd00 (tNetTask): dc0 - restarting device.
Background ERROR in Tcl code...........
error writing file14: S_errno_ENOBUFS
error writing file14: S_errno_ENOBUFS
while executing
"dp_sendTo ${::GrcUdpSock} "sta:ROC2 active 3675 0.0 438479 0.0"
${::GrcUdpAddr}"
("uplevel" body line 1)
invoked from within
"uplevel #0 dp_sendTo \${::GrcUdpSock} \"sta:[$obj cget -name] [$obj cget
-state] [$obj statistics]\" \${
::GrcUdpAddr}"
(procedure "::CODA::send_status" line 2)
invoked from within
"::CODA::send_status ROC2"