    I compared the scaler map defined in the odef file on both arms with the scaler.map used in the goxscaler, which I think is the most updated one. And they are consistent with each other. So if there is no mistake in the scaler.map, then it is probably the right u1 is not well plugged into HRS scaler. Since the pvdis daq has this signal all the time.

    The x3 saturated roughly around event # 5000K. We can also avoid this by stopping the run like 10minutes earlier.