• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT
    Make New Entry, Make Followup Entry

    User name R. Michaels

    Log entry time 22:01:23 on November 28, 2009

    Entry number 303393

    This entry is a followup to: 303373

    Followups:

    keyword=re: scalers

    Someone should analyze the scaler data differentially during a run.
    (We're talking about the HRS datastream, not the PVDIS/HAPPEX data).
    The data appears in the Podd output tree. I'm not set up to do it
    at home but I may try tomorrow.

    I think that at least the x3 should be able to work. The x10 is
    probably saturating and useless. At least one of the x1 is unplugged.

    Now why you might get -75 uA (neg) : probably a long run and the
    scaler overflows. Get a sign flip (32nd bit = sign). This can be
    seen by analyzing the scaler in tree as explained above. It's just
    a guess at this point because I've seen it before.

    Try "goxscaler" on adaq acct and see README