    User name R. Michaels

    Log entry time 02:11:20 on March22,2010

    Entry number 312735

    Followups:

    keyword=weird sieve

    Water cell runs with 10 nA and sieve slits

    Sieve pattern looks crazy on both L-HRS and R-HRS.

    Although it shouldn't matter much, we notice the septum
    magnet was set 1.5% too high along with the main HRS dipole.
    I think you want to leave septum alone (it matches
    the 5 degrees to 12.5 degrees). We set the current
    to 719.3 Amps. But this didn't change the picture.

    Runs 26776 and 6189.

    sieve still looks weird. fig 1. notice the extremely
    broad range in angles. The histogram limits are normally
    much smaller.

    thinking ...



    FIGURE 1