    User name V. Sulkosky

    Log entry time 19:11:04 on February 03, 2011

    Entry number 346056

    This entry is a followup to: 346043

    keyword=Resets for Fastbus crates

    The crate resets for the Fastbus crates have been tested and all work.  But
    first I had to remove the SFI unit from ROC 9, since the jumper was 
    incorrect to accept the reset signal.  After changing the jumper, ROC 9
    now resets remotely.  
    
    Thanks to Tai for assisting me in protecting the wire chamber ribbon 
    cables during the procedure.
    


    A copy of this log entry has been emailed to: nmuangma,lselvy,orchen,igorko,brads,kelleher,rshneor