NEXT
Make New Entry,
Make Followup Entry
User name V. Sulkosky
Log entry time 19:11:04 on February 03, 2011
Entry number 346056
This entry is a followup to: 346043
keyword=Resets for Fastbus crates
The crate resets for the Fastbus crates have been tested and all work. But
first I had to remove the SFI unit from ROC 9, since the jumper was
incorrect to accept the reset signal. After changing the jumper, ROC 9
now resets remotely.
Thanks to Tai for assisting me in protecting the wire chamber ribbon
cables during the procedure.
A copy of this log entry has been emailed to: nmuangma,lselvy,orchen,igorko,brads,kelleher,rshneor