April 29th 2024
From Hall A Wiki
- Updates
- Updates
- Active analyzer
- no signal
- HCAL
- need sync reset for the HCAL FADC
- sync reset for MPD at prestart
- will send a trigger to MPD
- FADC VTP reset need to be moved to prestart
- HCal trigger efficiency, some channels HV were lowered because they were noisy
- Updates
- RF time
- missing RF time in HCal side , 290 ns window in F1, 160 ns between RF prescaled. Around 10% maybe. All in 1190.
- maybe next access put copy in another F1 channel
- RF might be on a group with high rate - could add one more F1
- will investigate more
- RF time
- CDet
- no major updates
- HV computer needs to be fixed
- started making the ribbon cables from detector to repeater
- discussing putting patch panels on the detector, need to check there are no interferences
- need cables from detector to patch pannels : short 2 to 4 meters - check if existing ones can be reused
168 short SHV 168 short ribbon