December 18th 2020
From Hall A Wiki
- Updates
- HCAL
- taking LED data
- BB shower
- no trigger on shower
- Bryan looked at triggers - not many triggers going in - need to check trigger
- Hodoscope
- Bryan still need to gate data, gates coming in - check gate polarity
- 64 out of 90 bars
- HV one channel was tripping all board of 48 - Arun will try to fix it - have found all parts -
- GEM
- UVA clean room : still need to take data with adding additionnal cable
- UVA LV for next week in TEDF
- INFN : SSP readout - some APV disconnected - no triggers going in - MPD 17 disabled - MPD 18 and 3 2 and 6 - no more error message using MPDVme configuration - no trigger - will need to check - one last pedestal run MPD 17 all card have different noise panel - more fluctuations - 17 and 18 using same LV - maybe voltage drop when configuration - configure fine but not getting back data - check read back config
- GEM TEDF : took some CODA3 runs - cannot run several PEB - Bryan has instructions to set up port to fix that - DAQ can lend a server - will set up PEB on atedf3 for now
APV check program - Bryan could see the APV.
- GRINCH : still powered - Bradley tried to run CODA3 - Bryan still working on updating to the latest driver - new library has config files - GTP not included - working on upgrading
- HRS
- CODA3 on HRS DAQ : 1 Fastbus crate working with new readout list with help of Bryan and Dave - student will join to help - 3 TIs on hand - will start setting up the other Fastbus
- CDet
- finished collecting cosmics - to be analyzer
- everything shut down for winter break - will work on next module next year
- analyzer set up on clrlpc, trying to compile the read out list - need to find library for scalers
- new Linux for CPUs : new setup using new linux to boot - will upgrade HCal later
- leave crates on so Bryan can test up systems
- will run on clrlpc
- RP and active scintillator
- what version used ? - library fadc-HallB
- PXE boot from atedf3