Left Gas Cerenkov
From Hall A Wiki
Gas Cerenkov Specifics
- 100 (150) cm CO2
- ten spherical mirrors with 80 cm focal length
- viewed by 5" PMTs
PMT
Burle 8854
HV cable numbering
Channel HV Slot HV Channel ====================================== 1 2 0 2 2 1 3 2 2 4 2 3 5 2 4 6 2 5 7 2 6 8 2 7 9 2 8 10 2 9
Patch Panel, ADC and TDC numbering
For the delay cables, we use the Alfred row A patch panel.
Patch Panel GC Cable ADC TDC Channel ROC/Slot/Channel ROC/Slot/Channel --------------------------------------------------------------------- 1 1 3/25/32 4/13/80 2 2 3/25/33 4/13/81 3 3 3/25/34 4/13/82 4 4 3/25/35 4/13/83 5 5 3/25/36 4/13/84 6 6 3/25/37 4/13/85 7 7 3/25/38 4/13/86 8 8 3/25/39 4/13/87 9 9 3/25/40 4/13/88 10 10 3/25/41 4/13/89 11 "OR" 3/25/42 4/13/90