  • progress
    • after checking optics, Boris polarization is still low and dropping. see [1]
    • finished AFP loss test for Cell Gravy. see details [2]
  • todo
      • Use the Moss cell to check system again.
        • masing effect for Moss cell ( polarization ~ 20%), details see [3] and [4]
        • set up the gradient coil
        • test different currents and thresholds
        • test the new method to destroy target chamber polarization for diffusion model.
      • if system OK. we will do following (2 weeks):temperature optimization and diffusion test (225~240, may add point 220)
        • temperature stabilized ~ 4 hours
        • spin up. Note:
          • field sweep
          • 12sweep * 2 hours ( if spin up time > 6hours),
          • 15sweep * 1 hours ( if spin up time < 6hours)
        • do EPR
        • do internal temperature test. Note:
          • do NMR field sweep: laser on - off - on - off- on, each time temperature should be stabilized, ~ 20min), total: 1.5 hour
        • do AFP loss with laser on( do both field sweep and freq sweep, temperature stabilized)
          • do NMR field sweep 5~10 sweeps, check immediately,if not stable, should use 10 sweeps.Note:
          • then do NMR freq sweep 5~ 10 sweeps, check immediately,if not stable, should use 10 sweeps.
          • then do one field sweep- do one frequency sweep - do one field sweep - do one frequency sweep - do one field sweep- do one freq sweep, when begin to measure, click on loaddata, no need to change phase now.
          • purpose: to get the signal ratio of FIELD SWEEP/FREQ SWEEP, to do cross calibration ( EPR and water calibration)
        • do diffusion model ~ 6 hours. Note:
          • it is better to use field sweep for diffusion, click loaddata when run the program
          • 37 sweep *10 min
        • wait for another 3~6 hour( polarization is become stable),or we can put it in diffusion test.
          • purpose: it depends on the results of destroying polarization, if polarization is high and stable, we can ignore this step.
        • do AFP loss with laser off, using field sweep( temperature stabilized, 5~ 10 sweeps),check immediately
        • do hot spin-down, field sweep ~ 10 sweep * 2 hours
        • do one cold spin down for this cell after finishing all temperature tests ~18 hours
        • have any question about above procedures, please call me (Jie: 434-327-7584).


  • Calendar
timeline Tasks To be done by status
new cell
04/18-05/02 receiving from UVa Jie and Zhiwen
oven bottom piece
04/18-05/02 design and make oven bottom piece Zhiwen and Yawei
04/24-04/27 set up gradient coil and test Yawei and Jie
diffusion model measurement
04/27-05/09 do the test all
Dominic test
05/09-05/19 set up the comet laser and do the test all
pulse NMR
05/19-? pNMR setup and test Jie