Difference between revisions of "G2p Expert Shifts"

From Hall A Wiki
Jump to: navigation, search
(Information for Expert Shift Workers)
(Run Information)
 
(13 intermediate revisions by 3 users not shown)
Line 4: Line 4:
 
Here is the expert shift [https://docs.google.com/spreadsheet/ccc?key=0AsefZmXxYRr7dFlqRVdmMVhOWXJUV2J4cGRQaUtLcUE&hl=en_US#gid=0 schedule]
 
Here is the expert shift [https://docs.google.com/spreadsheet/ccc?key=0AsefZmXxYRr7dFlqRVdmMVhOWXJUV2J4cGRQaUtLcUE&hl=en_US#gid=0 schedule]
  
Student Shift Run [https://hallaweb.jlab.org/wiki/images/1/15/Student_shift_run_sheet.pdf Sheets]
+
Student shift run [https://docs.google.com/presentation/d/1fTld41QeZ3PML_4jAcWmqZ6OXJz_GiBA9CHsAhvgiTQ/edit sheets]
 +
 
 +
Blank run [https://hallaweb.jlab.org/wiki/images/f/ff/StudentShiftRunSheet2.pdf sheets]
  
 
===Run Information===
 
===Run Information===
 +
*CHECK THAT 3rd SHIFT WORKER IS FILLING OUT RUN SHEETS FOR EVERY RUN!
 
*Monitor [https://hallaweb.jlab.org/wiki/index.php/G2p_DAQ_How-To#Deadtime_Monitor deadtime], check that prescale values are appropriate
 
*Monitor [https://hallaweb.jlab.org/wiki/index.php/G2p_DAQ_How-To#Deadtime_Monitor deadtime], check that prescale values are appropriate
 
*Monitor edtm [https://hallaweb.jlab.org/wiki/index.php/G2p_DAQ_How-To#How_to_start_xscaler_.28HRS.29_.2F_view_the_scalers scalers]
 
*Monitor edtm [https://hallaweb.jlab.org/wiki/index.php/G2p_DAQ_How-To#How_to_start_xscaler_.28HRS.29_.2F_view_the_scalers scalers]
Line 12: Line 15:
 
**LHRS: LHRS
 
**LHRS: LHRS
 
**RHRS: RHRS
 
**RHRS: RHRS
 +
*Check HRS and septum currents for consistency.
 +
*Check BPM Strip chart for stable beam positions (BPMs are locked by MCC)
  
 
===Beamline===
 
===Beamline===
*Beam charge asymmetry  
+
*Check beam charge asymmetry
 +
**Check beam charge asymmetry for one run every 3~4 hours: type "asym L" or "asym R" or "asym TA" in adaq account, halog the result!
 
**Check charge asymmetry [https://hallaweb.jlab.org/wiki/index.php/Beam_charge_asymmetry_stripchart strip chart]
 
**Check charge asymmetry [https://hallaweb.jlab.org/wiki/index.php/Beam_charge_asymmetry_stripchart strip chart]
*Check for false asymmetry using [https://hallaweb.jlab.org/wiki/index.php/G2p_DAQ_How-To#How_to_start_xscaler_.28HRS.29_.2F_view_the_scalers scalers/lumis]
+
 
*check happex beam current asym: type "asym" or "asym L" or "asym R" in adaq account
+
 
*check BPM: type "spot++" or "spot_L" or "spot_R" in adaq account
 
*check BPM: type "spot++" or "spot_L" or "spot_R" in adaq account
  
Line 30: Line 35:
 
*Do full replay for every run (front room will only replay 20,000 events)
 
*Do full replay for every run (front room will only replay 20,000 events)
 
*Check that all ROCs are getting [https://hallaweb.jlab.org/wiki/index.php/G2p_DAQ_How-To#Checking_for_Gates gates]
 
*Check that all ROCs are getting [https://hallaweb.jlab.org/wiki/index.php/G2p_DAQ_How-To#Checking_for_Gates gates]
 +
 +
===Third Arm===
 +
*Check the start-of-run and end-of-run information in the halog. If they are not right, stop the run and restart CODA.
 +
*Do full replay for every run

Latest revision as of 11:48, 14 April 2012

Information for Expert Shift Workers

Below is a checklist of responsibilities for g2p student shift workers.

Here is the expert shift schedule

Student shift run sheets

Blank run sheets

Run Information

  • CHECK THAT 3rd SHIFT WORKER IS FILLING OUT RUN SHEETS FOR EVERY RUN!
  • Monitor deadtime, check that prescale values are appropriate
  • Monitor edtm scalers
  • Check that correct CODA configuration is being used
    • LHRS: LHRS
    • RHRS: RHRS
  • Check HRS and septum currents for consistency.
  • Check BPM Strip chart for stable beam positions (BPMs are locked by MCC)

Beamline

  • Check beam charge asymmetry
    • Check beam charge asymmetry for one run every 3~4 hours: type "asym L" or "asym R" or "asym TA" in adaq account, halog the result!
    • Check charge asymmetry strip chart
  • check BPM: type "spot++" or "spot_L" or "spot_R" in adaq account
  • Monitor bleedthrough current

Target

  • Monitor target polarization
    • Check that TO is actively adjusting nmr to maximize polarization.
    • Check that target is moved to 2nd cup/annealed when polarization drops too low

Replay

  • Do full replay for every run (front room will only replay 20,000 events)
  • Check that all ROCs are getting gates

Third Arm

  • Check the start-of-run and end-of-run information in the halog. If they are not right, stop the run and restart CODA.