Difference between revisions of "Monday, April 30, 2012 4:00pm"
From Hall A Wiki
Line 12: | Line 12: | ||
== Minutes == | == Minutes == | ||
* Detector work to be completed before next collaboration meeting | * Detector work to be completed before next collaboration meeting | ||
− | ** | + | ** standalone optics simulations for quartz (Jon) |
− | ** development of detector classes | + | *** code developed for and benchmarked against PREx for NIM paper |
− | ** | + | *** put in quartz shape/lightguide geometry for MOLLER |
+ | *** eventually checked in mollersim | ||
+ | ** development of mollersim for detectors (Peiqing) | ||
+ | *** detector geometry into | ||
+ | *** development of detector classes | ||
+ | *** benchmark to Qweak | ||
* Design issues: | * Design issues: | ||
** shape of lightguide | ** shape of lightguide | ||
Line 22: | Line 27: | ||
** structure of simulation | ** structure of simulation | ||
** parameterization so that changes can be easily accommodated | ** parameterization so that changes can be easily accommodated | ||
+ | *Other simulation projects of interest | ||
+ | ** collimator optimization (Jon, KK, Juliette) | ||
+ | ** coil placement sensitivity study (Jon, Juliette, KK) | ||
+ | *Other topics related to detectors | ||
+ | ** | ||
<br><br> Return to [[Teleconferences]] | <br><br> Return to [[Teleconferences]] | ||
<br> Return to [[MOLLER at 11 GeV E09-005]] | <br> Return to [[MOLLER at 11 GeV E09-005]] |
Revision as of 17:16, 30 April 2012
Agenda
- Detector work to be completed before next collaboration meeting
- detector geometry into mollersim
- standalone optics simulations for quartz
- other new work that could be presented by the collaboration meeting
- How to divide simulation work
- Peiqing - put in detector geometry and work on detector class(es?) including optical constant messengers, etc.?
- Jon - stand-alone code with results double-checked in mollersim?
Minutes
- Detector work to be completed before next collaboration meeting
- standalone optics simulations for quartz (Jon)
- code developed for and benchmarked against PREx for NIM paper
- put in quartz shape/lightguide geometry for MOLLER
- eventually checked in mollersim
- development of mollersim for detectors (Peiqing)
- detector geometry into
- development of detector classes
- benchmark to Qweak
- standalone optics simulations for quartz (Jon)
- Design issues:
- shape of lightguide
- shape of quartz
- placement of quartz
- Simulation issues:
- structure of simulation
- parameterization so that changes can be easily accommodated
- Other simulation projects of interest
- collimator optimization (Jon, KK, Juliette)
- coil placement sensitivity study (Jon, Juliette, KK)
- Other topics related to detectors
Return to Teleconferences
Return to MOLLER at 11 GeV E09-005