Difference between revisions of "G2p BCM calibration"
From Hall A Wiki
(→Analysis and scripts) |
(→Tungsten Calorimeter Calibration Results) |
||
Line 10: | Line 10: | ||
===Tungsten Calorimeter Calibration Results === | ===Tungsten Calorimeter Calibration Results === | ||
− | happex | + | happex C=slope*875us*(ΔA-ped*ΔEntry)) |
− | + | scaler SIS3800 & SIS3801 C=slope*(ΔA-ped*ΔEntry) | |
− | scaler C=slope*(ΔA-ped*ΔEntry) | + | |
− | calibration constant can find in: [ | + | |
+ | |||
+ | calibration constant can find in: [http://hallaweb.jlab.org/experiment/g2p/collaborators/pzhu/wiki/bcm\ calibration.ods here] | ||
==New Hall A 2 channel BCM receiver 1H00== | ==New Hall A 2 channel BCM receiver 1H00== |
Revision as of 11:15, 29 May 2012
Contents
Tungsten calorimeter
Introduction
Analysis and scripts
you can find the script in: /adaqfs/home/adaq/pzhu/bcm/tungsten
Tungsten Calorimeter Calibration Results
happex C=slope*875us*(ΔA-ped*ΔEntry)) scaler SIS3800 & SIS3801 C=slope*(ΔA-ped*ΔEntry)
calibration constant can find in: calibration.ods here