Difference between revisions of "How to open high voltage GUI"
From Hall A Wiki
(New page: * Instructions for opening high voltage GUI for spectrometers * login to adaql1 as adev (eg: "ssh adev@adaql1") * change directory to slowc (do "cd slowc") * For LHRS) |
|||
Line 1: | Line 1: | ||
* Instructions for opening high voltage GUI for spectrometers | * Instructions for opening high voltage GUI for spectrometers | ||
− | * login to adaql1 as adev (eg: "ssh adev@adaql1") | + | * login to adaql1 as adev (eg: "ssh adev@adaql1", passwords are written on a note in the counting house) |
* change directory to slowc (do "cd slowc") | * change directory to slowc (do "cd slowc") | ||
− | * | + | * To open Left HRS HV GUI do "./hvs Left" |
+ | * To open Right HRS HV GUI do "./hvs Right" |
Revision as of 14:59, 7 March 2014
- Instructions for opening high voltage GUI for spectrometers
- login to adaql1 as adev (eg: "ssh adev@adaql1", passwords are written on a note in the counting house)
- change directory to slowc (do "cd slowc")
- To open Left HRS HV GUI do "./hvs Left"
- To open Right HRS HV GUI do "./hvs Right"