Difference between revisions of "FADC DAQ"

From Hall A Wiki
Jump to: navigation, search
(Known Issues and Firmware upgrade)
(Known Issues and Firmware upgrade)
Line 85: Line 85:
 
*[http://hallaweb.jlab.org/equipment/moller/fadc/updates/fadc_upgrade.html    Known FADC issues]*
 
*[http://hallaweb.jlab.org/equipment/moller/fadc/updates/fadc_upgrade.html    Known FADC issues]*
 
* Plan for upgrade
 
* Plan for upgrade
**      FADC firmware upgrading
+
*      FADC firmware upgrading
  
*** We considering the possibility to have more counters array and programable logic  
+
  We considering the possibility to have more counters array and programable logic  
 
   unit (PLU) on the board of FADC  to programming a single channel coincidence  
 
   unit (PLU) on the board of FADC  to programming a single channel coincidence  
 
   and counting it on the scalers.
 
   and counting it on the scalers.
Line 97: Line 97:
 
   The module type of  LeCroy-2365 can be used as prototype for this PLU.
 
   The module type of  LeCroy-2365 can be used as prototype for this PLU.
  
*** Preliminary PLU parameters:
+
* Preliminary PLU parameters:
  
 
       16 inputs by 16 outputs, with possibility to provide the connection  
 
       16 inputs by 16 outputs, with possibility to provide the connection  
Line 103: Line 103:
 
       (OR), (AND) for inputs and function (NOT) for outputs.
 
       (OR), (AND) for inputs and function (NOT) for outputs.
 
        
 
        
*** The programmable registers(read/write):
+
* The programmable registers(read/write):
  
 
       16 registers ( 16bit) for AND function (every bit is corresponded to one input,  
 
       16 registers ( 16bit) for AND function (every bit is corresponded to one input,  
Line 111: Line 111:
 
       one (16bit) register for NOT function of output (every bit is corresponded to one output).
 
       one (16bit) register for NOT function of output (every bit is corresponded to one output).
 
        
 
        
*** Scalers array:   
+
* Scalers array:   
  
 
       16 channel of 32bit counters connected to the corresponded outputs of the PLU.
 
       16 channel of 32bit counters connected to the corresponded outputs of the PLU.
  
  
*** Add the possibility to disable generation of "Data trigger" at all and enable only trigger from helicity.
+
* Add the possibility to disable generation of "Data trigger" at all and enable only trigger from helicity.
  
 
= Literature=
 
= Literature=

Revision as of 13:14, 22 November 2016

Return to Moller wiki

Original_Moller_FADC_page(fadc)

Documentation

DAQ

FADC Documentation

CODA Startup

  • FADC CODA is running on hamoller computer under moller account.
To start CODA one can type command:
start_coda_fadc - that fires up the usual set of windows for ET, ER, EB, etc.
For FADC DAQ fadc_moller configuration in CODA RunControl is used.
  • FADC parameters.
There is configuration file with settable parameters for FADC.
File is located in directory: ~moller/crl/FADC/fadc_params.cnf
Parameters from file are loaded to FADC in Prestart state of CODA.

There is self explained list of FADC parameters from configuration file:

# Wed Apr 21 16:22:20 EDT 2010
# FADC settable parameters
# Threshold on calorimeter sums (define triggers and SW scaler logic)
FA_SUM_THRESH_CR 8500
FA_SUM_THRESH_CL 8500
# Threshold on individual channels
# Define SW scaler logic for Scintillators only
# Controls digitized data output for all channels (ie. 'zero-suppression')
FA_CHN_THRESH_SR 500
FA_CHN_THRESH_SL 500
FA_CHN_THRESH_CR 500
FA_CHN_THRESH_CL 500
## Prescale range: 1--2047
FADC_PRESCALE_CL 1000
FADC_PRESCALE_CR 1000
FADC_PRESCALE_CRL 200
## These many DATA trigger are grouped into each DATA interrupt
FADC_EVENTS_PER_BLOCK 20
## PULSE_WIDTH range is from 3--255 (3 is default)
FADC_PULSE_WIDTH 3
## COIN_WIDTH range is from 1--255 (2 is default)
FADC_COIN_WINDOW 2
## Delays range: 1--255
FADC_DELAY_CL 0
FADC_DELAY_CR 0
FADC_DELAY_SL_0 1
FADC_DELAY_SL_1 1
FADC_DELAY_SL_2 1
FADC_DELAY_SL_3 1
FADC_DELAY_SR_0 1
FADC_DELAY_SR_1 1
FADC_DELAY_SR_2 1
FADC_DELAY_SR_3 1
## This delay is for the _delay counts (random background measure)
FADC_DELAY_SRL 25
  • Data stored on hamoller computer to directory: /data1/raw/

Analysis

Useful tips

Known Issues and Firmware upgrade

  We considering the possibility to have more counters array and programable logic 
  unit (PLU) on the board of FADC  to programming a single channel coincidence 
  and counting it on the scalers.
  For example:
     sumLS.and.CL2.and.CR2,
     sumLS.and.CL2.and.sumCR, ...  and so on.
  The module type of  LeCroy-2365 can be used as prototype for this PLU.
  • Preliminary PLU parameters:
     16 inputs by 16 outputs, with possibility to provide the connection 
     of any inputs to any output through the logic function of
     (OR), (AND) for inputs and function (NOT) for outputs.
     
  • The programmable registers(read/write):
      16 registers ( 16bit) for AND function (every bit is corresponded to one input, 
                            the register number is corresponded to the output number), 
      16 registers ( 16bit) for OR function (every bit is corresponded to one input, 
                            the register number is corresponded to the output number)
      one (16bit) register for NOT function of output (every bit is corresponded to one output).
      
  • Scalers array:
     16 channel of 32bit counters connected to the corresponded outputs of the PLU.


  • Add the possibility to disable generation of "Data trigger" at all and enable only trigger from helicity.