Difference between revisions of "BigBite/RemoteCrateReset"

From Hall A Wiki
Jump to: navigation, search
(ROC8/ROC9/ROC10 /ROC14/ROC15)
Line 34: Line 34:
 
   Using controller IP: bbcamac1.jlab.org.  I/O reg in slot 11
 
   Using controller IP: bbcamac1.jlab.org.  I/O reg in slot 11
 
   Using cnaf command:  './cnafb'
 
   Using cnaf command:  './cnafb'
 +
 +
=== ROC14 ===
 +
log into hareboot6 using a web browser, usual password for APC, and reboot port 3
 +
 +
=== ROC15 ===
 +
log hatsv40 2008
 +
 +
hit Q to go back to the menu
 +
and C to display the crate informations again
 +
Hit then O to turn the crate off and O again to turn it back

Revision as of 18:56, 26 November 2008

Remote Crate Resets

There are a few ways to reboot the BigBite DAQ crates (TS12, ROC5, ROC6, ROC7, ROC9, ROC10).

TS12

  • Type "reboot" in the portserver terminal window
  • Direct a webbrowser to hareboot30, and perform an "Immediate Reboot".

ROC5

  • Type "reboot" in the portserver terminal window
  • Direct a webbrowser to hareboot26, and perform an "Immediate Reboot" for the switch labeled ROC5 - bbvme1.

ROC6/ROC7

  • Type "reboot" in the portserver terminal window
  • Direct a webbrowser to hareboot28, and perform an "Immediate Reboot".

ROC8/ROC9/ROC10

  • Type "reboot" in the portserver terminal window. If it doesn't work then
  • Log into an adaq machine using the adaq account... e.g.
[adaq@adaql4 adaq]$ ssh adaq@adaql1

Run "crate_reset roc8" for example to reset roc8

[adaq@adaql1 adaq]$ crate_reset
USAGE: /adaqfs/home/adaq/brad/camac_control/crate_reset [options] <rocID> [<rocID> ... ]
  -v     verbose.
  -h     This help text.
---
 rocID   Channel   Description
 -----   -------   -----------
 roc10     10      Lower FASTBUS TDC crate
 roc8       8      FASTBUS ADC crate
 roc9       9      Upper FASTBUS TDC crate
 ts2        2      Electron Trigger Supervisor
---
 Using controller IP: bbcamac1.jlab.org.  I/O reg in slot 11
 Using cnaf command:  './cnafb'

ROC14

log into hareboot6 using a web browser, usual password for APC, and reboot port 3

ROC15

log hatsv40 2008

hit Q to go back to the menu and C to display the crate informations again Hit then O to turn the crate off and O again to turn it back