= Overview = | = Overview = | ||
Line 27: | Line 31: | ||
* Shift checklist | * Shift checklist | ||
− | == | + | == Analyzing the Data == |
This section contains instructions for running the replay script with all detectors on a-onl@aonlX. | This section contains instructions for running the replay script with all detectors on a-onl@aonlX. | ||
+ | |||
+ | === Instruction for shift crew === | ||
+ | * Login to a-onl@aonlX (X=1, 2, 3, 4) | ||
+ | * once logged in, type ''gosbs'' => this takes you to the directory where the analysis should be done, and sets up the correct environment variables. | ||
+ | * type ''./run_gmn_50k.sh runnum'' with | ||
+ | ** ''runnum'' (integer) the run number you want to analyze; | ||
+ | * This analyses the first 50000 events and produces plots that need to be checked. | ||
+ | * Please review all produced plots of each GUI, and click on "Exit GUI", this will pop the next GUI. | ||
+ | * After you're reviewed all plots, they will be saved as PDFs. | ||
+ | |||
+ | * '''Instructions for full replay to be updated''' After a run is completed, you may run ''./run_gmn_all runnum firstseg nseg'' with: | ||
+ | ** ''runnum'' having the same definition as above; | ||
+ | ** ''firstseg'' being the first segment to analyze; | ||
+ | ** ''nseg'' the number of segments to analyze. | ||
+ | |||
+ | === Specific instructions for experts === | ||
+ | '''''Note''': these instructions are likely to evolve in a very near future'' | ||
* Login to a-onl@aonlX (X=1, 2, 3, 4) | * Login to a-onl@aonlX (X=1, 2, 3, 4) | ||
* once logged in, type ''gosbs'' => this takes you to the directory where the analysis should be done, and sets up the correct environment variables. | * once logged in, type ''gosbs'' => this takes you to the directory where the analysis should be done, and sets up the correct environment variables. | ||
* open the analyzer by typing ''analyzer'' | * open the analyzer by typing ''analyzer'' | ||
− | * once in the analyzer type ''.L replay_gmn.C'' | + | * once in the analyzer type ''.L replay_gmn.C+'' |
− | * | + | * type ''replay_gmn(runnum, nevents, firstevent, file_prefix, firstsplit, nsplits, pedestalmode)'' with: |
− | ** ''runnum'' the run number you want to analyze; | + | ** ''runnum'' (integer) the run number you want to analyze; |
− | ** ''nevents'' the number of events you want to analyze. | + | ** ''nevents'' (long integer) the number of events you want to analyze. |
− | * '' | + | ** ''firstevent'' (long integer) the event number from which you want to start the analysis; |
− | + | ** ''file_prefix'' (char*)the prefix of the file you want to analyze; | |
− | ** ''file_prefix'' the prefix of the file you want to analyze; | + | ** ''firstsplit'' (integer) the split/segment number at which you want to start the analysis; |
− | ** ''firstsplit'' the split/segment number at which you want to start the analysis; | + | ** ''nsplits'' (integer) the number of splits/segments you want to analyze |
− | ** ''nsplits'' the number of splits/segments you want to analyze | + | ** ''pedestalmode'' (integer) turn pedestal mode on or off for the GEMs |
= Recovery Procedures = | = Recovery Procedures = | ||
Line 76: | Line 97: | ||
* [[Corrector Magnets]] | * [[Corrector Magnets]] | ||
* [[LHRS for GMn]] | * [[LHRS for GMn]] | ||
+ | |||
+ | == EDTM == | ||
+ | *[[How to Set EDTM Frequency with the DVCS Pulser]] | ||
== Detectors == | == Detectors == | ||
Line 83: | Line 107: | ||
* GEMs | * GEMs | ||
* GRINCH | * GRINCH | ||
+ | ** [[Grinch Gas Panel Camera]] | ||
* Timing Hodoscope | * Timing Hodoscope | ||
* Preshower and Shower | * Preshower and Shower | ||
**[[How to adjust discriminator threshold on HCAL DAC]] | **[[How to adjust discriminator threshold on HCAL DAC]] | ||
**[[How to run the scalers script to monitor trigger sum scalers]] | **[[How to run the scalers script to monitor trigger sum scalers]] | ||
+ | |||
=== Super BigBite === | === Super BigBite === | ||
* GEMs | * GEMs | ||
* HCAL | * HCAL | ||
+ | **[[HCal Overview]] |
Latest revision as of 12:54, 21 October 2021
THIS IS THE OLD/DEPRECATED SBS SHIFT HOW-to PAGE!!!
To access the new wiki page, follow this link to the new how-to page
Overview
This page gives instructions for various aspects of the experiment relating to each of the major subsystems and shift tasks.
Shift Roles
- Shift Leader: Executes the Run Plan according to the Run Coordinator's instructions
- Target Operator: Monitors the target system
- Data Quality Monitor: Starts and stops CODA DAQ runs and monitors the quality of the data that is being recorded
Reporting and Logging
All shift takers should regularly log shift details in HALOG - the Hall A electronic logbook.
Shift leaders should fill out Beam Time Accounting (BTA) information during the shift.
Taking Data
- Using the CODA DAQ
- GUI Description
- Starting a Run
- Stopping a Run
- Monitoring the data
- Online analysis
- Shift checklist
Analyzing the Data
This section contains instructions for running the replay script with all detectors on a-onl@aonlX.
Instruction for shift crew
- Login to a-onl@aonlX (X=1, 2, 3, 4)
- once logged in, type gosbs => this takes you to the directory where the analysis should be done, and sets up the correct environment variables.
- type ./run_gmn_50k.sh runnum with
- runnum (integer) the run number you want to analyze;
- This analyses the first 50000 events and produces plots that need to be checked.
- Please review all produced plots of each GUI, and click on "Exit GUI", this will pop the next GUI.
- After you're reviewed all plots, they will be saved as PDFs.
- Instructions for full replay to be updated After a run is completed, you may run ./run_gmn_all runnum firstseg nseg with:
- runnum having the same definition as above;
- firstseg being the first segment to analyze;
- nseg the number of segments to analyze.
Specific instructions for experts
Note: these instructions are likely to evolve in a very near future
- Login to a-onl@aonlX (X=1, 2, 3, 4)
- once logged in, type gosbs => this takes you to the directory where the analysis should be done, and sets up the correct environment variables.
- open the analyzer by typing analyzer
- once in the analyzer type .L replay_gmn.C+
- type replay_gmn(runnum, nevents, firstevent, file_prefix, firstsplit, nsplits, pedestalmode) with:
- runnum (integer) the run number you want to analyze;
- nevents (long integer) the number of events you want to analyze.
- firstevent (long integer) the event number from which you want to start the analysis;
- file_prefix (char*)the prefix of the file you want to analyze;
- firstsplit (integer) the split/segment number at which you want to start the analysis;
- nsplits (integer) the number of splits/segments you want to analyze
- pedestalmode (integer) turn pedestal mode on or off for the GEMs
Recovery Procedures
Systems
High Voltage
Alarms
Beam Line
- Monitoring the Beam Line
- Hall A beam line drawing (to be updated)
- SBS checkout procedure
- SBS spot++ (beam size verification)
- SBS BPM calibration
- SBS HARP scan
- SBS Polarization Measurements
- Compton: Not Used
- SBS Moller
Target
Magnets
EDTM
Detectors
BigBite
- GEMs
- GRINCH
- Timing Hodoscope
- Preshower and Shower
Super BigBite
- GEMs
- HCAL