Difference between revisions of "Polhe3 Metal Windows"
From Hall A Wiki
(→Window Pressure Test Setup) |
|||
Line 21: | Line 21: | ||
| [[Image:Ptest9_cp-100-T_17nov2011.jpg|thumb|upright|220px|Regulator gauges: Right to left: Tank pressure P=600psig. Output pressure P=137psig.]] | | [[Image:Ptest9_cp-100-T_17nov2011.jpg|thumb|upright|220px|Regulator gauges: Right to left: Tank pressure P=600psig. Output pressure P=137psig.]] | ||
|} | |} | ||
+ | === Beryllium Foil Material === | ||
+ | The company [http://materion.com/Businesses/Electrofusion/Products/ProductGroups/Beryllium/BerylliumX-Ray.aspx Materion Electrofusion] supplies various purity Be foil for the X-ray window industry. They provide the following grades: | ||
+ | |||
+ | * [http://materion.com/Businesses/Electrofusion/Products/ProductGroups/Beryllium/BerylliumX-Ray/~/media/Files/PDFs/Electrofusion/EQF3007_PF60.pdf PF-60 Beryllium High Purity Foil] - 99.0% Be | ||
+ | * [http://materion.com/Businesses/Electrofusion/Products/ProductGroups/Beryllium/BerylliumX-Ray/~/media/Files/PDFs/Electrofusion/EQF3008_PS200.pdf PS-200 Beryllium Standard Purity Foil] - 98.5% Be |
Revision as of 21:22, 3 April 2012
Window Pressure Test Setup
- Investigating the possibility of using Larson glass to metal seals as a means to couple metal windows to glass target chamber.
- Pressure test setup was assembled at UVa to test glass to metal seals at typical target cell operating pressures.
- Initial test on a Larson CP-100-T Pyrex glass to Copper metal seal (1-inch O.D.) performed on Nov 16 & 17, 2001. Test piece was pressurized to approximately 10-atm (137psig) of argon for 24hrs. The glass to metal seal did not explode. Although, 10-atm is low (typical target operating pressure is 12-atm to 13-atm). No leak tests on the seal have been performed during this initial pressure test. We still need to establish that gas will not leak thru seal at high pressures.
- Ultimately, we would like to place a thin metal window (such as beryllium) on the metal end and then pressure test both the metal window and the glass to metal seal at pressures greater than 12-atm to 13-atm.
- In the future, we will investigate whether it is possible to make a GE180 glass to metal seal and if it will stay leak tight at high pressures.
Beryllium Foil Material
The company Materion Electrofusion supplies various purity Be foil for the X-ray window industry. They provide the following grades:
- PF-60 Beryllium High Purity Foil - 99.0% Be
- PS-200 Beryllium Standard Purity Foil - 98.5% Be