- Report by E. Jensen on the rates in the coordinate detector.
- Study of resolution by Mark Jones
- Point target with 4.4 +/- 0.2 GeV electrons. Front face of calorimeter is 526cm from target.
- 3 planes of scintillator planes with 0.5cm thickness, 134cm long and 3cm width.
- each plane is 268 bars with the middle plane offset by .25cm
- 15cm absober block in front.
- Throw electron for vertical and horizontal angle of +/-0.12 radians.
- Tables of resolutions and efficiencies with different thresholds
Threshold (MeV) | Eff | sigma (mm) |
3 | 0.90 | 1.01 |
4 | 0.89 | 0.98 |
4.5 | 0.87 | 0.95 |
5 | 0.84 | 0.94 |
5.5 | 0.75 | 1.02 |
6 | 0.63 | 1.06 |